Navien · Air conditioner
E813 Inverter trip: Compressor starting error
What the control is telling you
Inverter trip error shown after alarm 863 occurred four times. Manual reset needed (display shows 813).
Applies to: NAE28V3622A1, NAE28V6022A1
Likely causes
- Current or voltage sensor failure
- Poor wiring contact
- Overload or compressor motor failure
- Unstable input voltage
- Noise and interference
- Low refrigerant or heavy load
Test and repair steps
- Turn off power at the disconnect before opening the unit.
- Check the supply voltage.
- Check the compressor.
- Check wiring and connections.
- Check refrigerant charge.
- Check the sensors.
- Replace the inverter.
Models that show this code
2 models in Navien NAE
Other codes on the same units
- E809 Inverter trip: Overcurrent at ID current limit
- E810 Inverter trip: Hardware compressor overcurrent
- E811 Inverter trip: PFC overcurrent
- E812 Inverter trip: Estimator fault
- E814 Inverter trip: Wire miss error
- E815 Inverter trip: Heatsink over temperature
- E816 Inverter trip: DC under voltage
- E817 Inverter trip: DC over voltage
Save it for the next call
Star this code in the HVACopedia app and keep the whole library on your phone for jobs with no signal.
Source: Navien NAE I&O manual (07/2026), 7.1 Error table and 7.2.30, p.60. Summarized in our own words; check the original manual for your model.
Homeowner looking at this code? See what it means for you and when to call a technician.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.