Navien · Air conditioner
E810 Inverter trip: Hardware compressor overcurrent
What the control is telling you
Inverter trip error shown after alarm 860 occurred four times. Manual reset needed (display shows 810).
Applies to: NAE28V3622A1, NAE28V6022A1
Likely causes
- Low or no outdoor airflow
- Supply voltage problem
- Loose or wrong wiring
- Phase imbalance
- Refrigerant overcharge
- Inverter damage
- Compressor internal damage
- Overload from abnormal refrigerant pressure, blocked line or low oil
Test and repair steps
- Turn off power at the disconnect before opening the unit.
- Check compressor current against its rating.
- Check refrigerant charge.
- Check power and wiring.
- Replace the inverter.
- Replace the compressor if needed.
Models that show this code
2 models in Navien NAE
Other codes on the same units
- E806 Inverter trip: Input voltage sensor error
- E807 Inverter trip: Software compressor overcurrent
- E808 Inverter trip: Overcurrent at compressor current limit
- E809 Inverter trip: Overcurrent at ID current limit
- E811 Inverter trip: PFC overcurrent
- E812 Inverter trip: Estimator fault
- E813 Inverter trip: Compressor starting error
- E814 Inverter trip: Wire miss error
Save it for the next call
Star this code in the HVACopedia app and keep the whole library on your phone for jobs with no signal.
Source: Navien NAE I&O manual (07/2026), 7.1 Error table and 7.2.27, p.59. Summarized in our own words; check the original manual for your model.
Homeowner looking at this code? See what it means for you and when to call a technician.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.