Navien · Air conditioner

E207 Compressor temperature abnormal error

High severity Navien NAE

What the control is telling you

Shown after alarm A257 has occurred four times. Manual reset needed (display shows 207).

Applies to: NAE28V3622A1, NAE28V6022A1

Likely causes

  • Refrigerant leak
  • TXV malfunction
  • Compressor malfunction

Test and repair steps

  1. Turn off power at the disconnect before opening the unit.
  2. Check for refrigerant leaks.
  3. Check the TXV.
  4. Check the compressor and its connector on the mainboard.
  5. Check the TD and TS sensors.
  6. Check the inverter.
  7. Replace the compressor if it is the fault.

Models that show this code

2 models in Navien NAE

NAE28V3622A1NAE28V6022A1

Other codes on the same units

  • E203 Compressor discharge temperature (TD) protection error
  • E204 Compression ratio (CR) protection error
  • E205 Overcurrent (CUR) protection error
  • E206 Heatsink protection error
  • E208 Compressor suction temperature (TS) protection error
  • E209 Superheat protection error
  • E210 High pressure switch (HPS) protection error
  • E501 Outdoor temperature sensor (Ta) open/short

Save it for the next call

Star this code in the HVACopedia app and keep the whole library on your phone for jobs with no signal.

Open the app

Source: Navien NAE I&O manual (07/2026), 7.1 Error table and 7.2.7, p.49. Summarized in our own words; check the original manual for your model.

Homeowner looking at this code? See what it means for you and when to call a technician.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.