Goodman furnace error codes

131 codes (79 faults, 52 normal display and menu codes), plus 4 settings tables.

CodeMeaningSeverity / type
1 flashLockout - three failed ignition triesHigh
1ACCooling, low stageNormal status
2 flashesPressure switch stuck closedHigh
2ACCooling, high stageNormal status
3 flashesPressure switch stuck openHigh
4 flashesPrimary or auxiliary limit openHigh
5 flashesFlame sensed with no call for heatCritical
6 flashesRollout limit open or control fuse blownHigh
7 flashesLow flame signalMedium
8 flashesIgniter relay faultHigh
9 flashesTwinning faultMedium
10 flashesOpen fuse - no 24 V at the controlMedium
11 flashesIgniter openHigh
12 flashesInducer relay faultHigh
88Power-up self checkNormal status
AC1Cooling, low stage (communicating)Normal status
AC2Cooling, high stage (communicating)Normal status
b0Blower motor not runningHigh
b1Lost communication with blower motorHigh
b2Blower motor size does not match model dataMedium
b3Blower motor limiting (power, temperature or speed)Medium
b4Blower motor trip (lost rotor control or high current)High
b5Blower motor locked rotorHigh
b6Blower motor over/under voltage or over temperatureHigh
b7Blower motor missing parametersMedium
b9Low indoor airflowMedium
C1Low-stage coolingNormal status
C2High-stage coolingNormal status
d0No shared data on the controlHigh
d4Memory card data rejectedMedium
dF1Defrost, low-stage gas heatNormal status
dF2Defrost, high-stage gas heatNormal status
E0Lockout - ignition failed 3 timesHigh
E1Low-stage pressure switch closed at start of heatMedium
E2Low-stage pressure switch will not closeHigh
E3High limit or rollout limit openHigh
E4Flame sensed with no call for heatCritical
E5Control fuse openMedium
E6Low flame signalLow
E7Igniter circuit faultHigh
E8High-stage pressure switch closed at start of heatMedium
E9High-stage pressure switch will not closeMedium
E10Grounding fault / poor neutral connectionHigh
E11Flame rollout switch openCritical
E12Redundant relay openHigh
E13Redundant relay stuck closedHigh
Eb0Blower motor not runningHigh
Eb1Lost communication with blower motorHigh
Eb2Blower motor hp does not match model dataMedium
Eb3Blower motor running in power, temperature or speed limitMedium
Eb4Blower motor current trip or lost rotor controlHigh
Eb5Blower motor locked rotorHigh
Eb7Blower motor missing parametersHigh
Eb9Inadequate airflowMedium
Ec1Network communication alarmMedium
Ec2E-module network communication alarmMedium
Ec3Bluetooth module network communication alarmLow
Ed0No shared data on the networkMedium
Ed1Invalid data on networkMedium
Ed4Memory card data rejectedMedium
Ed5Invalid downloaded firmwareMedium
Ed6Unrecognized data IDMedium
EE0Lockout - too many ignition retries (3)High
EE1Pressure switch closed at start of heating cycleMedium
EE2Pressure switch did not close (inducer runs, no ignition)Medium
EE3High (primary) limit openHigh
EE4Flame sensed with no call for heatCritical
EE5Open fuse (short in low voltage wiring)Medium
EE6Low flame signalLow
EE8High-stage pressure switch closed at start of heating cycleMedium
EE9High-stage pressure switch did not closeMedium
gH1Gas heat, low stageNormal status
gH2Gas heat, high stageNormal status
HP1Heat pump heat, low stageNormal status
HP2Heat pump heat, high stageNormal status
L0Low-stage heatNormal status
L6FLast 6 faults (view and clear)Menu / mode display
SH1Special heat relay 1Normal status
SH2Special heat relay 2Normal status
ACCooling, single stageNormal status
AxxAirflow readoutNormal status
CFM readoutAirflow number (CFM / 100)Menu / mode display
CFSComfort settingMenu / mode display
CrCode release numberMenu / mode display
EA115 V polarity reversedHigh
EEAReversed line polarity or grounding errorHigh
EECInternal gas valve error - valve energized when it should not beCritical
EEEInternal control fault (IRQ loss)High
EEFCondensate switch openMedium
EEHTwinning errorLow
EEJInducer relay errorHigh
EELIgniter relay / igniter circuit faultHigh
EEbExternal gas valve error - valve not energized when it should beHigh
EEdCondensate or auxiliary alarm switch openMedium
EEnIgniter openHigh
EOLOEM test modeMenu / mode display
ErrActive alarm menuMenu / mode display
FContinuous fanNormal status
FAnContinuous fanNormal status
HEdHumidifier enableMenu / mode display
HIHigh-stage heatNormal status
HPHeat pump heat, single stageNormal status
HUdHumidifier onNormal status
IdLIdle - no callNormal status
LED offNo LED - no power or control failureHigh
LED steady onNormal operationNormal status
LrnLearn menuMenu / mode display
OPNormal - waiting for a callNormal status
Rapid flashReversed polarityHigh
Red LED 1 flashRed communications LED 1 flash - communication failureMedium
Red LED 2 flashesRed communications LED 2 flashes - reset in progressMenu / mode display
Red LED offRed communications LED off - normalNormal status
Rx LED 1 steady flashGreen receive LED single steady flash - no network foundLow
Rx LED offGreen receive LED off - no power or communications errorMedium
Rx LED on solidGreen receive LED on solid - data lines miswired or shortedMedium
Rx LED rapid flashGreen receive LED rapid flashing - normal network trafficNormal status
SrShared data revisionMenu / mode display
dHLDehumidify logic input levelMenu / mode display
dHUDehumidifier onNormal status
gAFGas heat airflowMenu / mode display
gFdGas heat fan off delayMenu / mode display
gHGas heat, single stageNormal status
gPtGas pressure testMenu / mode display
gStGas heat stage multiplierMenu / mode display
gbPBackup heat balance pointsMenu / mode display
gndGas heat fan on delayMenu / mode display
gtFGas heat trim factorMenu / mode display
rFdReset to factory defaultsMenu / mode display
uACInverter coolingNormal status
uHPInverter heat pump heatNormal status
utLVentilator onNormal status

Settings and specs

Normal status displays (7-segment)

Installer menu · Goodman/Amana GM9S96/AM9S96

ModeDisplay
IdleIdL
Continuous fanFAn
Cooling, low stage1AC
Cooling, high stage2AC
Gas heat (single stage)gH
Factory (OEM) test modeEOL
  • These are normal operating displays, not fault codes.

Source: Goodman RS6612022r1 (GM9S92/GM9S96/GC9S96 service), 1 Stage Status Codes - Status Menu p.28

Normal status displays (7-segment)

Installer menu · Goodman/Amana GM9S80/AM9S80

ModeDisplay
IdleIdL
Continuous fanFAn
Cooling, low stage1AC
Cooling, high stage2AC
Gas heat (single stage)gH
Factory (OEM) test modeEOL
  • These are normal operating displays, not fault codes.

Source: Goodman RS6621008r2 (GM9S80 service), 1 Stage Status Codes - Status Menu p.31

Normal status displays (7-segment)

Installer menu · Goodman/Amana GM9C96/AM9C96

ModeDisplay
IdleIdL
Continuous fanFAn
Cooling, low stage1AC
Cooling, high stage2AC
Gas heat, low stagegH1
Gas heat, high stagegH2
Factory (OEM) test modeEOL
  • These are normal operating displays, not fault codes.

Source: Goodman RS6612020r1 (GM9C96 service), 2 Stage Status Codes p.34

Models covered

*CVC960403BNB**CVC960603BNB**CVC960804CNB**CVC961005CNB**CVC961205DNB**MVC960403BNB**MVC960603BNB**MVC960803BNB**MVC960804CNB**MVC961005CNB**MVC961005DNB**MVC961205DNB*AC9C96AC9S800403ANAC9S800603ANAC9S800804BNAC9S800805CNAC9S801005CNAC9S960403BNAC9S960603BNAC9S960804CNAC9S961005CNAC9S961205CNAC9S961205DNACES96ACES960403BNAAACES960603BNAAACES960804CNAAACES961005CNAAACES961205DNAAACVC96AM9C96AM9C960303ANAM9S800403ANAM9S800603ANAM9S800603BNAM9S800604BNAM9S800803BNAM9S800804BNAM9S800804CNAM9S800805CNAM9S801005CNAM9S801205DNAM9S920403ANAM9S920603BNAM9S920803BNAM9S920804CNAM9S920805CNAM9S921004CNAM9S921005CNAM9S921205DNAM9S960403ANAM9S960603BNAM9S960803BNAM9S960804CNAM9S960805CNAM9S961004CNAM9S961005CNAM9S961205DNAMES92AMES920403ANAAAMES920603BNAAAMES920803BNAAAMES920804CNAAAMES920805CNAAAMES921004CNAAAMES921005CNAAAMES921205DNAAAMES96AMES960403ANAAAMES960603BNAAAMES960803BNAAAMES960804CNAAAMES960805CNAAAMES961005CNAAAMES961205DNAAAMVC96GC9C96GC9S800403ANGC9S800603ANGC9S800804BNGC9S800805CNGC9S801005CNGC9S960403BNGC9S960603BNGC9S960804CNGC9S961005CNGC9S961205CNGC9S961205DNGCES96GCES960403BNAAGCES960603BNAAGCES960804CNAAGCES961005CNAAGCES961205DNAAGCVC90704CXGCVC90905DXGCVC91155DXGCVC950714CXGCVC950915DXGCVC96GM9C96GM9C960303ANGM9S800403ANGM9S800603ANGM9S800603BNGM9S800604BNGM9S800803BNGM9S800804BNGM9S800804CNGM9S800805CNGM9S801005CNGM9S801205DNGM9S920403ANGM9S920603BNGM9S920803BNGM9S920804CNGM9S920805CNGM9S921004CNGM9S921005CN

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.