Goodman · Furnace
Eb4 Blower motor current trip or lost rotor control
What the control is telling you
The motor lost rotor control or drew high current, so the furnace stopped.
Applies to: GMVC96, GCVC96, AMVC96, ACVC96 (*BA, ComfortBridge)
Likely causes
- Sudden change in motor load, speed or torque
- Sudden blockage at the furnace air inlet or outlet
Test and repair steps
- Turn off power before touching wiring or the board.
- Check the filter, grilles, registers, ducts and the furnace air inlet and outlet for blockage.
Settings for these units
- Normal status displays (7-segment) · Goodman/Amana GM9S96/AM9S96
- Normal status displays (7-segment) · Goodman/Amana GM9S80/AM9S80
- Normal status displays (7-segment) · Goodman/Amana GM9C96/AM9C96
- Minimum recommended filter size · Goodman/Amana GM9C96/AM9C96
Models that show this code
16 models in Goodman/Amana *MVC96 (34.5 in. chassis)
Other codes on the same units
- Eb0 Blower motor not running
- Eb1 Lost communication with blower motor
- Eb2 Blower motor hp does not match model data
- Eb3 Blower motor running in power, temperature or speed limit
- Eb5 Blower motor locked rotor
- Eb6 Blower motor over/under voltage or over temperature
- Eb7 Blower motor missing parameters
- Eb9 Inadequate airflow
Save it for the next call
Star this code in the HVACopedia app and keep the whole library on your phone for jobs with no signal.
Source: Goodman Service and Troubleshooting ACVC96*BA/AMVC96*BA/GCVC96*BA/GMVC96*BA , Alarm Code Table p.56 / Troubleshooting Chart p.63. Summarized in our own words; check the original manual for your model.
Homeowner looking at this code? See what it means for you and when to call a technician.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.