Goodman · Furnace

Rx LED off Green receive LED off - no power or communications error

Medium severity Goodman/Amana *MVC95/*CVC9 two-stage ComfortNet

What the control is telling you

The green Rx LED is dark: either the furnace has no power or there is a communications error.

Applies to: GMVC95/AMVC95 upflow and *CVC9 counterflow two-stage furnaces

Likely causes

  • No power to the furnace
  • Open fuse
  • Short in low voltage wiring
  • Communications error

Test and repair steps

  1. Safety turn power off before working on the control or wiring.
  2. Check breakers and the 3 A control fuse. Replace a blown fuse with the same type.
  3. Look for shorts in the furnace and system low voltage wiring.
  4. Press the learn button to reset the network.
  5. Check the data 1 / data 2 voltages (see the ComfortNet data line guide).

Settings for these units

Models that show this code

10 models in Goodman/Amana *MVC95/*CVC9 two-stage ComfortNet

GCVC90704CXGCVC90905DXGCVC91155DXGCVC950714CXGCVC950915DXGMVC950453BXGMVC950704CXGMVC950905CXGMVC950905DXGMVC951155DX

Other codes on the same units

Save it for the next call

Star this code in the HVACopedia app and keep the whole library on your phone for jobs with no signal.

Open the app

Source: Goodman *CVC9/95 & *MVC95 Installation Instructions IO-341D (08/2010), Network Troubleshooting p.47. Summarized in our own words; check the original manual for your model.

Homeowner looking at this code? See what it means for you and when to call a technician.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.