Goodman · Furnace

CFM readout Airflow number (CFM / 100)

Menu / mode display Goodman/Amana *MVC95/*CVC9 two-stage ComfortNet

What the display is showing

A number like 12 alternating with the mode letters is the airflow being delivered, rounded to the nearest 100 CFM. 12 = about 1200 CFM (1225 shows 12, 1275 shows 13). Use it to check your blower tap settings.

Applies to: GMVC95/AMVC95 upflow and *CVC9 counterflow two-stage furnaces

Settings for these units

Models that show this code

10 models in Goodman/Amana *MVC95/*CVC9 two-stage ComfortNet

GCVC90704CXGCVC90905DXGCVC91155DXGCVC950714CXGCVC950915DXGMVC950453BXGMVC950704CXGMVC950905CXGMVC950905DXGMVC951155DX

Other codes on the same units

  • L0 Low-stage heat
  • EA 115 V polarity reversed
  • F Continuous fan
  • HI High-stage heat
  • OP Normal - waiting for a call
  • Red LED 1 flash Red communications LED 1 flash - communication failure
  • Red LED 2 flashes Red communications LED 2 flashes - reset in progress
  • Red LED off Red communications LED off - normal

Save it for the next call

Star this code in the HVACopedia app and keep the whole library on your phone for jobs with no signal.

Open the app

Source: Goodman *CVC9/95 & *MVC95 Installation Instructions IO-341D (08/2010), Status Codes p.58; Circulator Blower Speeds p.40. Summarized in our own words; check the original manual for your model.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.