Goodman · Furnace

b3 Blower motor limiting (power, temperature or speed)

Medium severity Goodman/Amana *MVC95/*CVC9 two-stage ComfortNet

What the control is telling you

The motor is running in a limit mode. The furnace runs, but airflow is lower than it should be.

Applies to: GMVC95/AMVC95 upflow and *CVC9 counterflow two-stage furnaces

Likely causes

  • Dirty filter
  • Restricted ductwork
  • Undersized ductwork
  • High ambient temperature around the furnace

Test and repair steps

  1. Check and clean or replace the filter.
  2. Check ducts for blockage and open all registers.
  3. If ducts are undersized for the system, they need to be resized.
  4. Check the furnace location is not too hot.

Settings for these units

Models that show this code

10 models in Goodman/Amana *MVC95/*CVC9 two-stage ComfortNet

GCVC90704CXGCVC90905DXGCVC91155DXGCVC950714CXGCVC950915DXGMVC950453BXGMVC950704CXGMVC950905CXGMVC950905DXGMVC951155DX

Other codes on the same units

  • b0 Blower motor not running
  • b1 Lost communication with blower motor
  • b2 Blower motor size does not match model data
  • b4 Blower motor trip (lost rotor control or high current)
  • b5 Blower motor locked rotor
  • b6 Blower motor over/under voltage or over temperature
  • b7 Blower motor missing parameters
  • b9 Low indoor airflow

Save it for the next call

Star this code in the HVACopedia app and keep the whole library on your phone for jobs with no signal.

Open the app

Source: Goodman *CVC9/95 & *MVC95 Installation Instructions IO-341D (08/2010), Troubleshooting Chart p.53-57. Summarized in our own words; check the original manual for your model.

Homeowner looking at this code? See what it means for you and when to call a technician.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.