Goodman · Furnace

b4 Blower motor trip (lost rotor control or high current)

High severity Goodman/Amana *MVC95/*CVC9 two-stage ComfortNet

What the control is telling you

The blower motor lost rotor control or saw high current and shut down. Furnace will not run. ComfortNet thermostat shows MOTOR TRIPS b4.

Applies to: GMVC95/AMVC95 upflow and *CVC9 counterflow two-stage furnaces

Likely causes

  • Sudden load change on the motor
  • Sudden blockage of the furnace air inlet or outlet
  • Very high load: blocked filter, very restrictive ducts

Test and repair steps

  1. Safety turn power off before working on the control or wiring.
  2. Check the filter, return grilles, registers, ducts and the furnace inlet and outlet for blockage.
  3. Clear the restriction and run the furnace again.

Settings for these units

Models that show this code

10 models in Goodman/Amana *MVC95/*CVC9 two-stage ComfortNet

GCVC90704CXGCVC90905DXGCVC91155DXGCVC950714CXGCVC950915DXGMVC950453BXGMVC950704CXGMVC950905CXGMVC950905DXGMVC951155DX

Other codes on the same units

  • b0 Blower motor not running
  • b1 Lost communication with blower motor
  • b2 Blower motor size does not match model data
  • b3 Blower motor limiting (power, temperature or speed)
  • b5 Blower motor locked rotor
  • b6 Blower motor over/under voltage or over temperature
  • b7 Blower motor missing parameters
  • b9 Low indoor airflow

Save it for the next call

Star this code in the HVACopedia app and keep the whole library on your phone for jobs with no signal.

Open the app

Source: Goodman *CVC9/95 & *MVC95 Installation Instructions IO-341D (08/2010), Troubleshooting Chart p.53-57. Summarized in our own words; check the original manual for your model.

Homeowner looking at this code? See what it means for you and when to call a technician.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.