Goodman · Furnace

E6 Low flame signal

Low severity Goodman/Amana *MVC95/*CVC9 two-stage ComfortNet

What the control is telling you

The furnace still runs, but the flame sensor current is low. If it gets worse the furnace will start locking out. ComfortNet thermostat shows WEAK FLAME E6.

Applies to: GMVC95/AMVC95 upflow and *CVC9 counterflow two-stage furnaces

Likely causes

  • Coated or oxidized flame sensor
  • Sensor not sitting in the flame
  • Lazy flame from wrong gas pressure or poor combustion air

Test and repair steps

  1. Safety turn power off before working on the control or wiring.
  2. Clean the flame sensor with emery cloth.
  3. Check the sensor sits in the burner flame.
  4. Check the intake pipe for blockage, length, elbows and termination.
  5. Check gas pressure against the rating plate and adjust if needed (gas tech only).

Settings for these units

Models that show this code

10 models in Goodman/Amana *MVC95/*CVC9 two-stage ComfortNet

GCVC90704CXGCVC90905DXGCVC91155DXGCVC950714CXGCVC950915DXGMVC950453BXGMVC950704CXGMVC950905CXGMVC950905DXGMVC951155DX

Other codes on the same units

  • E1 Low-stage pressure switch closed at start of heat
  • E2 Low-stage pressure switch will not close
  • E3 High limit or rollout limit open
  • E4 Flame sensed with no call for heat
  • E5 Control fuse open
  • E7 Igniter circuit fault
  • E8 High-stage pressure switch closed at start of heat
  • E9 High-stage pressure switch will not close

Save it for the next call

Star this code in the HVACopedia app and keep the whole library on your phone for jobs with no signal.

Open the app

Source: Goodman *CVC9/95 & *MVC95 Installation Instructions IO-341D (08/2010), Troubleshooting Chart p.53-57. Summarized in our own words; check the original manual for your model.

Homeowner looking at this code? See what it means for you and when to call a technician.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.