Goodman · Furnace

gH1 Gas heat, low stage

Normal status Goodman/Amana GM9C96/AM9C96

What the display is showing

Shown while the two-stage furnace is heating on low fire. Normal operation during a call for heat.

Applies to: GM9C96/AM9C96 two-stage furnaces

Settings for these units

Normal status displays (7-segment) · Goodman/Amana GM9C96/AM9C96

ModeDisplay
IdleIdL
Continuous fanFAn
Cooling, low stage1AC
Cooling, high stage2AC
Gas heat, low stagegH1
Gas heat, high stagegH2
Factory (OEM) test modeEOL

These are normal operating displays, not fault codes.

Minimum recommended filter size · Goodman/Amana GM9C96/AM9C96

ConfigurationSize codeMinimum filter
Upflow*0403A*1 - 16 x 25 side or 1 - 14 x 24 bottom return
Upflow*0603A*1 - 16 x 25 side or 14 x 24 bottom return
Upflow*0603B*1 - 16 x 25 side or bottom return
Upflow*0803B*1 - 16 x 25 side or bottom return
Upflow*0804B*1 - 16 x 25 side or bottom return
Upflow*0804C*1 - 16 x 25 side or bottom return
Upflow*0805C*1 - 16 x 25 side or bottom return (see note 1)
Upflow*0805D*2 - 16 x 25 side or 1 - 20 x 25 bottom return (see note 1)
Upflow*1004C*2 - 16 x 25 side or 1 - 20 x 25 bottom return
Upflow*1005C*2 - 16 x 25 side or 1 - 20 x 25 bottom return
Upflow*1205D*2 - 16 x 25 side or 1 - 24 x 24 bottom return
Downflow*0403A*2 - 10 x 20 or 1 - 14 x 25 top return

Note 1: with a cooling unit over 4 tons use 2 - 16 x 25 filters on two side returns or a 20 x 25 on the bottom return.

Upflow at 1800 CFM or more: use two side returns or one side plus bottom.

Models that show this code

6 models in Goodman/Amana GM9C96/AM9C96

AC9C96AM9C96AM9C960303ANGC9C96GM9C96GM9C960303AN

Other codes on the same units

  • EE3 High (primary) limit open
  • EE4 Flame sensed with no call for heat
  • EE5 Open fuse (short in low voltage wiring)
  • EE6 Low flame signal
  • EE8 High-stage pressure switch closed at start of heating cycle
  • EE9 High-stage pressure switch did not close
  • gH2 Gas heat, high stage
  • L6F Last 6 faults (view and clear)

Save it for the next call

Star this code in the HVACopedia app and keep the whole library on your phone for jobs with no signal.

Open the app

Source: GM9C96 service RS6612020r1, 2 Stage Status Codes p.34. Summarized in our own words; check the original manual for your model.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.