Carrier heat pump error codes
162 codes (141 faults, 21 normal display and menu codes).
| Code | Meaning | Severity / type |
|---|---|---|
| 1 | Normal operation - 1 flash | Normal status |
| 1 long | Capacity limited - one long flash | Normal status |
| 2 | Normal operation - 2 flashes (high stage) | Normal status |
| 3 | Three flashes - outdoor fan delay after defrost active (24ANB/25HNB) | Normal status |
| 4 | Four flashes - speed limiting (25VNA8) / fan delay defeat on (24ANB/25HNB) | Normal status |
| 5 | Five flashes - brownout protection setting (24ANB/25HNB) | Normal status |
| 6 | Six flashes - brownout protection setting (24ANB/25HNB) | Normal status |
| 16 | Lost communication with user interface | Medium |
| 25 | Invalid model plug / inverter size | High |
| 31 | High pressure switch open | High |
| 32 | Low pressure trip | Medium |
| 33 | Lost inverter communication | Medium |
| 45 | Outdoor control board failure | High |
| 46 | Brownout | Medium |
| 47 | No 230 V at unit | High |
| 48 | Lost inverter communication - lockout | High |
| 49 | Compressor over current | Medium |
| 53 | Outdoor air temperature sensor fault | Medium |
| 54 | Suction temperature sensor fault | Medium |
| 55 | Outdoor coil temperature sensor fault | Medium |
| 56 | OAT / coil thermistor out of range | Medium |
| 57 | Suction pressure transducer fault | Medium |
| 59 | Discharge temperature high (event) | Medium |
| 61 | Fan inverter fault | Medium |
| 63 | Fan inverter current fault | Medium |
| 65 | DC bus voltage low - speed limiting | Medium |
| 66 | Outdoor fan dropped out | Medium |
| 67 | Stator heater fault | Medium |
| 68 | 10-minute stage 2 warm-up delay | Low |
| 69 | Inverter / compressor internal fault | High |
| 71 | Compressor dropped out | Medium |
| 72 | Suction over temperature (event) | Medium |
| 73 | Contactor shorted | High |
| 74 | Discharge temperature lockout | High |
| 75 | Maximum power mode - temperature | Medium |
| 76 | Fan inverter lockout | High |
| 77 | Maximum power mode - compressor current | Medium |
| 79 | Compressor / inverter fault (failed start) | Medium |
| 81 | Low stage thermal lockout | High |
| 82 | Suction over temperature lockout | High |
| 83 | Low pressure lockout (4 hours) | High |
| 84 | High pressure lockout (4 hours) | High |
| 86 | Fan inverter current lockout | High |
| 88 | Compressor / inverter lockout | High |
| 91 | Inverter DC over voltage (event) | Medium |
| 92 | Inverter DC under voltage (event) | Medium |
| 95 | Compressor over current lockout | High |
| 96 | DC under voltage lockout | High |
| 97 | DC over voltage lockout | High |
| 98 | High torque event | Medium |
| 99 | High torque lockout | High |
| 341 MCE error | 341 MCE error | Medium |
| EC0d | ODU malfunction | High |
| EC07 | ODU fan speed out of control | Medium |
| EC51 | ODU EEPROM parameter error | High |
| EC52 | ODU coil temp sensor error | Medium |
| EC53 | ODU ambient temp sensor error | Medium |
| EC54 | COMP. discharge temp sensor error | Medium |
| EC56 | IDU coil outlet temp sensor error | Medium |
| ECC1 | Other IDU refrigerant sensor detects leakage (multi-zone) | High |
| EH00 | IDU EEPROM malfunction | High |
| EH0A | IDU EEPROM parameter error | High |
| EH0E | Water-level alarm malfunction | Medium |
| EH0b | IDU main control and display boards communication error | Medium |
| EH03 | IDU fan speed out of control | Medium |
| EH3A | External fan DC bus voltage too low protection | Medium |
| EH3b | External fan DC bus voltage too high fault | Medium |
| EH60 | IDU room temp. sensor (T1) error | Medium |
| EH61 | IDU coil temp. sensor (T2) error | Medium |
| EH62/EH66 | Evaporator coil inlet temp. sensor (T2B) open or short circuit | Medium |
| EH65 | Evaporator coil inlet temp. sensor (T2A) open or short circuit | Medium |
| EHb3 | Communication malfunction between wire controller and master control | Medium |
| EHC1 | Refrigerant sensor detects leakage | Critical |
| EHC2 | Refrigerant sensor out of range and leakage detected | Critical |
| EHC3 | Refrigerant sensor out of range | High |
| EL0C | System lacks refrigerant | High |
| EL01 | IDU & ODU communication error | Medium |
| EL16 | Communication malfunction between adapter board and outdoor main board | Medium |
| FL09 | Mismatch between the new and old platforms | Medium |
| LD1 | MOC red LED LD1 (sizes 25-60) | Normal status |
| LD5 | MOC green LED LD5 (sizes 25-60) | Normal status |
| LED1 | MOC red LED1 (sizes 25-60) | Normal status |
| LED3 | MOC amber LED3 (sizes 25-60) | Normal status |
| LED200 | MOC red LED (sizes 13, 24B) | Normal status |
| LED207 | MOC amber LED (sizes 13, 24B) | Normal status |
| PC00 | ODU IPM module protection | High |
| PC0L | Low ambient temp. protection | Low |
| PC01 | ODU voltage protection | High |
| PC02 | Compressor top (or IPM) temp. protection | High |
| PC03 | Pressure protection (low or high pressure) | High |
| PC04 | Inverter compressor drive error | High |
| ---- | Indoor units mode conflict | Medium |
| COMM LED | Green COMM LED on - communicating | Normal status |
| Charging mode | Refrigerant charging mode (25VNA8/24VNA9, communicating) | Menu / mode display |
| Curtailment | Utility curtailment shown on user interface | Normal status |
| DF | Defrost mode | Normal status |
| EC 07 | Outdoor fan speed operating outside normal range | Medium |
| EC 0d | Outdoor unit malfunction | Medium |
| EC 50 | Temperature sensor open or shorted | Medium |
| EC 51 | EEPROM malfunction (outdoor unit) | High |
| EC 52 | Outdoor temperature sensor open or short | Medium |
| EC 53 | Outdoor temperature sensor open or short | Medium |
| EC 54 | Outdoor temperature sensor open or short | Medium |
| EC 55 | Quick maintenance code (outdoor) | Medium |
| EC 56 | Outdoor temperature sensor open or short | Medium |
| EC 57 | Quick maintenance code (outdoor) | Medium |
| EC 5C | Quick maintenance code (outdoor) | Medium |
| EH 00 | EEPROM malfunction (indoor unit) | High |
| EH 03 | Indoor fan speed outside normal range | Medium |
| EH 03 / EC 07 | Fan speed outside normal range | Medium |
| EH 0A | EEPROM malfunction (indoor unit) | High |
| EH 0E | Water-level alarm malfunction | Medium |
| EH 0b | Indoor main control board and display board communication error | Medium |
| EH 3A | External fan DC bus voltage too low protection | Medium |
| EH 3b | External fan DC bus voltage too high fault | Medium |
| EH 60 | Indoor temperature sensor open or short | Medium |
| EH 61 | Indoor temperature sensor open or short | Medium |
| EH 62 | Indoor temperature sensor open or short | Medium |
| EH 65 | Indoor temperature sensor open or short | Medium |
| EH 66 | Indoor temperature sensor open or short | Medium |
| EH C1 | Refrigerant sensor detects leakage | High |
| EH C2 | Refrigerant sensor out of range and leakage detected | Critical |
| EH C3 | Refrigerant sensor out of range | Medium |
| EH b3 | Communication malfunction between wired controller and master control | Medium |
| EH bA | Communication malfunction between indoor unit and external fan module | Medium |
| EHbA | Communication error between indoor unit and external fan module | Medium |
| EL 01 | Indoor and outdoor unit communication error | Medium |
| EL 0C | System lacks refrigerant | Medium |
| EL 16 | Communication malfunction between adapter board and outdoor main board | Medium |
| FC | Forced cooling mode | Normal status |
| FH CC | Refrigerant sensor error | Medium |
| FHCC | Refrigerant sensor error | High |
| FL 09 | Mismatch between new and old platforms | Medium |
| Forced defrost | Forced defrost (short the defrost pins) | Menu / mode display |
| LC 06 | Compressor top (IPM) temperature protection | High |
| ON | Amber STATUS LED on solid - standby | Normal status |
| PC 00 | Outdoor IPM module protection | Critical |
| PC 01 | Outdoor voltage protection | High |
| PC 02 | Compressor top or IPM temperature protection | High |
| PC 03 | High or low pressure protection | High |
| PC 04 | Inverter compressor drive error | High |
| PC 06 | Quick maintenance code (outdoor) | High |
| PC 08 | Quick maintenance code (outdoor) | High |
| PC 0F | Quick maintenance code (outdoor) | High |
| PC 0L | Low ambient temperature protection | Medium |
| PC 0a | Quick maintenance code (outdoor) | High |
| PC 10 | Quick maintenance code (outdoor) | High |
| PC 11 | Quick maintenance code (outdoor) | High |
| PC 12 | Quick maintenance code (outdoor) | High |
| PC 30 | Quick maintenance code (outdoor) | High |
| PC 31 | Quick maintenance code (outdoor) | High |
| PC 40 | Quick maintenance code (outdoor) | High |
| PC 41 | Quick maintenance code (outdoor) | High |
| PC 42 | Quick maintenance code (outdoor) | High |
| PC 43 | Quick maintenance code (outdoor) | High |
| PC 44 | Quick maintenance code (outdoor) | High |
| PC 45 | Quick maintenance code (outdoor) | High |
| PC 46 | Quick maintenance code (outdoor) | High |
| PC 49 | Quick maintenance code (outdoor) | High |
| PH 90 | Quick maintenance code (outdoor) | High |
| PH 91 | Quick maintenance code (outdoor) | High |
| Status code recall | Status code recall mode (25VNA8/24VNA9) | Menu / mode display |
Models covered
25HCB625HNB62425HNB63625HNB64825HNB66025HNB92425HNB93625HNB94825HNB96025HPA625VNA81325VNA82425VNA82525VNA83625VNA83725VNA84825VNA86037MAHAQ37MARAQ37MGHAQ37MGRAQ37MUHA37MURACH17D5CSHAH06AAKD5CSHAH09AAKD5CSHAH12AAKD5CSHAH18AAKD5CSRAH09AAKD5CSRAH12AAKD5CSRAH18AAKD5CUHAH18AAKD5CUHAH24AAKD5CUHAH30AAKD5CUHAH36AAKD5CUHAH48AAKD5CUHAH60AAKD5CURA + D5MUWAD5CURAH18AAKD5CURAH24AAKD5CURAH30AAKD5CURAH36AAKD5CURAH48AAKD5CURAH60AAKD5FUAAH18AAKD5FUAAH24AAKD5FUAAH30AAKD5FUAAH36AAKD5FUAAH48AAKD5FUAAH60AAK
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.