Carrier · Heat pump
Charging mode Refrigerant charging mode (25VNA8/24VNA9, communicating)
What the display is showing
Mode on the Infinity user interface, opened from the Installation and Service screen, used to check or set refrigerant charge. The screen offers weigh-in or heating check charge methods; the heating check runs the system at stage 5 with matched outdoor fan and indoor airflow and counts down while it stabilizes. A service-valve subcooling option appears only when outdoor and indoor temperatures are in range, otherwise it is greyed out.
Applies to: Carrier Infinity 25VNA8/24VNA9 communicating systems
What to do
- On the Infinity control open Installation and Service, then Refrigerant Charging.
- Pick the charge method on the Charging Mode Selection screen.
- Wait for the stabilization countdown before reading pressures.
Models that show this code
7 models in Carrier Infinity 18VS 25VNA8
Other codes on the same units
Save it for the next call
Star this code in the HVACopedia app and keep the whole library on your phone for jobs with no signal.
Source: Carrier 25VNA8/24VNA9 service manual, Check Charge and Heating Check Chart Procedure, p.9-12. Summarized in our own words; check the original manual for your model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.