PC 00 Outdoor IPM module protection
What the control is telling you
The voltage signal the IPM sends to the compressor drive chip is abnormal. The LED shows PC 00 and the unit turns off. Recommended parts: connection wires, IPM module board, outdoor fan assembly, compressor, outdoor PCB.
Applies to: D5FUHA
Likely causes
- Wiring fault between PCB and compressor
- Faulty IPM board
- Outdoor fan or ventilation problem
- Compressor winding fault
- Faulty outdoor PCB
Test and repair steps
- Check the wiring between the PCB and the compressor. Fix or replace wires and connectors if there is an error.
- Check the IPM. If it is not working, replace the IPM board or the outdoor PCB.
- Check the outdoor fan and outdoor unit ventilation. If not working properly, follow the Fan Speed Out of Control solution (EH03/EC 07).
- Check the compressor resistance. If out of acceptable range, replace the compressor.
- If the compressor is within range, replace the outdoor PCB.
Other codes on the same units
Save it for the next call
Star this code in the HVACopedia app and keep the whole library on your phone for jobs with no signal.
Source: D5FUHA service manual, p. 30. Summarized in our own words; check the original manual for your model.
Homeowner looking at this code? See what it means for you and when to call a technician.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.