EC51 ODU EEPROM parameter error
What the control is telling you
Outdoor main chip gets no feedback from the EEPROM chip. Compressor drive chip EEPROM errors and communication errors between the outdoor main chip and compressor drive chip are handled the same way.
Applies to: D5FUHA outdoor unit
Likely causes
- Outdoor main chip not receiving feedback from the EEPROM
Test and repair steps
- Shut off the power and turn it back on 2 minutes later.
- If the code still shows, replace the outdoor main PCB.
- If the code clears, the unit operates normally.
Other codes on the same units
Save it for the next call
Star this code in the HVACopedia app and keep the whole library on your phone for jobs with no signal.
Source: Carrier D5FUHA service manual, p. 23. Summarized in our own words; check the original manual for your model.
Homeowner looking at this code? See what it means for you and when to call a technician.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.