Carrier · Heat pump

33 Lost inverter communication

Medium severity Carrier Infinity 18VS 25VNA8

What the control is telling you

Amber STATUS light flashes 33. No communication between the AOC board and the inverter (MOC) for 2 minutes. Becomes code 48 after 3 failures within 20 minutes or 20 minutes of continuous loss. Type: Local; reset: Automatic.

Applies to: Carrier Infinity 18VS variable speed heat pump 25VNA8 (AOC control + inverter)

Likely causes

  • See code 48 for causes

Test and repair steps

  1. Troubleshoot as code 48.

Models that show this code

7 models in Carrier Infinity 18VS 25VNA8

25VNA81325VNA82425VNA82525VNA83625VNA83725VNA84825VNA860

Other codes on the same units

  • 4 Four flashes - speed limiting (25VNA8) / fan delay defeat on (24ANB/25HNB)
  • 25 Invalid model plug / inverter size
  • 31 High pressure switch open
  • 32 Low pressure trip
  • 46 Brownout
  • 48 Lost inverter communication - lockout
  • 49 Compressor over current
  • 53 Outdoor air temperature sensor fault

Save it for the next call

Star this code in the HVACopedia app and keep the whole library on your phone for jobs with no signal.

Open the app

Source: Carrier 25VNA8 / 24VNA9 Service Manual, Table 6 Fault Code Actions, p.19. Summarized in our own words; check the original manual for your model.

Homeowner looking at this code? See what it means for you and when to call a technician.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.