3 Three flashes - outdoor fan delay after defrost active (24ANB/25HNB)
What the display is showing
On the 24ANB/25HNB heat pump, three flashes and a pause on the amber STATUS LED show the 20-second outdoor-fan delay after defrost is active (the factory setting). It appears while the forced defrost pins are shorted for more than 15 seconds in standby, and the LED returns to solid after the short is removed.
Applies to: Carrier 24ANB/25HNB two-stage heat pump
What to do
- Toggle with the forced defrost pins as described for code 4.
Models that show this code
8 models in Carrier 2-stage 24ANB/25HNB
Other codes on the same units
- 1 Normal operation - 1 flash
- 2 Normal operation - 2 flashes (high stage)
- 4 Four flashes - speed limiting (25VNA8) / fan delay defeat on (24ANB/25HNB)
- 5 Five flashes - brownout protection setting (24ANB/25HNB)
- 6 Six flashes - brownout protection setting (24ANB/25HNB)
- 16 Lost communication with user interface
- 25 Invalid model plug / inverter size
- 31 High pressure switch open
Save it for the next call
Star this code in the HVACopedia app and keep the whole library on your phone for jobs with no signal.
Source: Carrier residential A/C and heat pump service manual 24-25, two-stage defrost section (fan delay defeat), p.54-55. Summarized in our own words; check the original manual for your model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.