Carrier · Heat pump
1 Normal operation - 1 flash
What the display is showing
The amber STATUS LED gives one flash and a pause, repeating. This is a normal running indication, not a fault: on the 25VNA8/24VNA9 with an Infinity control it means variable capacity operation, and with a 2-stage thermostat it means low capacity. On the 24ANB/25HNB it means low stage cooling or heating, and on the single-stage communicating heat pump it means normal cooling or heating.
Applies to: Carrier Infinity 25VNA8/24VNA9 variable speed, 24ANB/25HNB two-stage and single-stage communicating outdoor units
Models that show this code
15 models in Carrier Infinity 18VS 25VNA8, Carrier 2-stage 24ANB/25HNB, Carrier single-stage communicating HP
Other codes on the same units
- 1 long Capacity limited - one long flash
- 2 Normal operation - 2 flashes (high stage)
- 3 Three flashes - outdoor fan delay after defrost active (24ANB/25HNB)
- 4 Four flashes - speed limiting (25VNA8) / fan delay defeat on (24ANB/25HNB)
- 5 Five flashes - brownout protection setting (24ANB/25HNB)
- 6 Six flashes - brownout protection setting (24ANB/25HNB)
- 16 Lost communication with user interface
- 25 Invalid model plug / inverter size
Save it for the next call
Star this code in the HVACopedia app and keep the whole library on your phone for jobs with no signal.
Source: Carrier 25VNA8/24VNA9 service manual, Table 6 Fault Code Actions (status rows), p.15-16; Carrier residential A/C and heat pump service manual 24-25, Table 14 Status Codes (single-stage communicating HP), p.50-51; Carrier residential A/C and heat pump service manual 24-25, Table 18 Troubleshooting (2-stage 24ANB/25HNB), p.60-61. Summarized in our own words; check the original manual for your model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.