Carrier · Heat pump
EH0A IDU EEPROM parameter error
What the control is telling you
Indoor EEPROM parameter error.
Applies to: D5FUHA indoor unit
Likely causes
- Indoor main chip not receiving feedback from the EEPROM
Test and repair steps
- Shut off the power and turn it back on 2 minutes later.
- If the code still shows, replace the indoor main PCB.
- If the code clears, the unit operates normally.
Other codes on the same units
- EC54 COMP. discharge temp sensor error
- EC56 IDU coil outlet temp sensor error
- ECC1 Other IDU refrigerant sensor detects leakage (multi-zone)
- EH00 IDU EEPROM malfunction
- EH0E Water-level alarm malfunction
- EH0b IDU main control and display boards communication error
- EH03 IDU fan speed out of control
- EH3A External fan DC bus voltage too low protection
Save it for the next call
Star this code in the HVACopedia app and keep the whole library on your phone for jobs with no signal.
Source: Carrier D5FUHA service manual, p. 23. Summarized in our own words; check the original manual for your model.
Homeowner looking at this code? See what it means for you and when to call a technician.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.