Carrier · Heat pump

91 Inverter DC over voltage (event)

Medium severity Carrier Infinity 18VS 25VNA8

What the control is telling you

Amber STATUS light flashes 91. Inverter DC voltage too high, e.g. the compressor suddenly unloaded. After 5 events it becomes code 97. Type: Local; reset: 5 minutes.

Applies to: Carrier Infinity 18VS variable speed heat pump 25VNA8 (AOC control + inverter)

Likely causes

  • Compressor suddenly unloaded - check service valves are fully open

Test and repair steps

  1. Check the service valves are fully open.
  2. If it repeats, troubleshoot as code 97.

Save it for the next call

Star this code in the HVACopedia app and keep the whole library on your phone for jobs with no signal.

Open the app

Source: Carrier 25VNA8 / 24VNA9 Service Manual, Table 6 Fault Code Actions, p.25. Summarized in our own words; check the original manual for your model.

Homeowner looking at this code? See what it means for you and when to call a technician.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.