Rinnai boiler error codes

108 codes (67 faults, 41 normal display and menu codes).

CodeMeaningSeverity / type
00-AParameter menu entryNormal status
021Too Long DHW Continuous OperationMedium
60Descaling countdown (minutes remaining)Menu / mode display
100Air intake/exhaust blockage or full condensate trapCritical
110Ignition failureHigh
120Flame failure (flame lost during operation)High
140Overheat switch tripped (heat exchanger overheating)Critical
150Venturi control faultHigh
161High outgoing temperatureHigh
170Venturi blockage / position mismatchHigh
180Gas valve air/fuel adjustment limit reachedHigh
190Electrical grounding / short in DC circuitHigh
210Data transfer errorMedium
220Gas valve position not detected (reed switch)Medium
250Condensate pump switch tripped (accessory)High
303Secondary system thermistor faultMedium
310Freeze protection thermistor faultMedium
321Outgoing Thermistor (Combi Only)Medium
331Heat Exchanger Thermistor (Combi Only)Medium
341Inlet Thermistor (Combi Only)Medium
353CH supply thermistor faultMedium
363CH return thermistor faultMedium
371Indirect tank thermistor faultMedium
380Exhaust thermistor faultMedium
393Outdoor temperature sensor faultMedium
400Water pressure sensor communication faultMedium
430High or low system water pressureHigh
443Low water cut-off (LWCO) activatedHigh
520Gas solenoid valve circuit – flame after valve closeCritical
540High exhaust (flue gas) temperatureCritical
610Combustion fan motor speed faultHigh
631DHW Recirculation Pump (Combi Only)Low
651Water Flow Control (Combi Only)Medium
661By-Pass (Combi Only)Medium
6703-Way Valves (Combi Only)Medium
681Hot Water Supply Temperature Abnormality (Combi Only)Medium
700PC Board faultHigh
710Gas solenoid circuit – valve position mismatchHigh
720Flame rod faultHigh
7630-10V external control input over-voltageMedium
831Indirect tank call running too longMedium
890Freeze condition detectedHigh
999PC Board / software mismatchHigh
E00Poor flame formation (flame sensed with burner off)High
E02No flame formation (ignition failure)High
E04Voltage interruption / error read-out interruptedMedium
E05Adjustment error (listed in short reference)Medium
E12High limit stat openHigh
E14Supply sensor T1 faultHigh
E18Maximum supply temperature exceededHigh
E19Maximum return temperature exceededHigh
E28Fan speed not reported backHigh
E31Supply sensor T1 shortedHigh
E32Return sensor T2 shortedHigh
E36Supply sensor T1 openHigh
E37Return sensor T2 openHigh
E69No or incorrect displayMedium
E393Outdoor sensor harness disconnectedMedium
E430Low water pressure in the heating systemHigh
SW1-SW3PC board buttons (SW1, SW2, SW3)Menu / mode display
A XXDe-aeration runningNormal status
Block 01External safety contact openMedium
Block 05Outdoor sensor not connectedLow
Block 60Wrong minimum/maximum power parameterMedium
Block 67Supply/return sensor difference with burner offMedium
Block 85No water flow detectedMedium
COdEAccess code entryMenu / mode display
CopyFactory settings restoredNormal status
ECLReset complete (gas solenoid circuit)Normal status
ERROError chapterMenu / mode display
EndDescaling completeMenu / mode display
FFFMaintenance performed markerLow
FHForced High Fire ModeNormal status
FILLWater pressure low / system emptyNormal status
FLForced Low Fire ModeNormal status
FUSE24 V fuse defectiveHigh
GoodGood state (normal)Normal status
Green button resetRestore factory parametersMenu / mode display
HIGHWater pressure too highNormal status
INFOInformation chapterMenu / mode display
Ignition safety testTest ionization lockoutMenu / mode display
LCLime scale detected on DHW sideMedium
PVenturi reset: first screenMenu / mode display
P XXWater pressure read-outNormal status
PARAParameter chapterMenu / mode display
PCLVenturi reset acceptedNormal status
Parameter modeParameter settings menuMenu / mode display
Perf dataPerformance data menuMenu / mode display
SESecondary unit error (cascade)Medium
SERVService chapterMenu / mode display
SERVICEService dueNormal status
SSService Soon reminderLow
STOPFill target reachedNormal status
StBYStandby / exit to read-outNormal status
Status 0No heat demandNormal status
Status 1Fan pre/post purgeNormal status
Status 2Ignition phaseNormal status
Status 3Burner on, central heatingNormal status
Status 4Burner on, domestic hot waterNormal status
Status 5Fan checkNormal status
Status 6Burner off, demand pendingNormal status
Status 7Pump overrun, central heatingNormal status
Status 8Pump overrun, hot waterNormal status
Status 9Burner off, supply temperature too highNormal status
Status AAutomatic de-aeration programNormal status
Technical read-outTechnical read-outMenu / mode display
dESDescaling (automated flush) modeMenu / mode display
rnSRinsing stage (descaling flush)Menu / mode display

Models covered

E110CRNE110CRPE50CRNE75CRNE75CRPIP060SIP090SIP120SIP150SIP175SIP199S

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.