Rinnai boiler error codes
108 codes (67 faults, 41 normal display and menu codes).
| Code | Meaning | Severity / type |
|---|---|---|
| 00-A | Parameter menu entry | Normal status |
| 021 | Too Long DHW Continuous Operation | Medium |
| 60 | Descaling countdown (minutes remaining) | Menu / mode display |
| 100 | Air intake/exhaust blockage or full condensate trap | Critical |
| 110 | Ignition failure | High |
| 120 | Flame failure (flame lost during operation) | High |
| 140 | Overheat switch tripped (heat exchanger overheating) | Critical |
| 150 | Venturi control fault | High |
| 161 | High outgoing temperature | High |
| 170 | Venturi blockage / position mismatch | High |
| 180 | Gas valve air/fuel adjustment limit reached | High |
| 190 | Electrical grounding / short in DC circuit | High |
| 210 | Data transfer error | Medium |
| 220 | Gas valve position not detected (reed switch) | Medium |
| 250 | Condensate pump switch tripped (accessory) | High |
| 303 | Secondary system thermistor fault | Medium |
| 310 | Freeze protection thermistor fault | Medium |
| 321 | Outgoing Thermistor (Combi Only) | Medium |
| 331 | Heat Exchanger Thermistor (Combi Only) | Medium |
| 341 | Inlet Thermistor (Combi Only) | Medium |
| 353 | CH supply thermistor fault | Medium |
| 363 | CH return thermistor fault | Medium |
| 371 | Indirect tank thermistor fault | Medium |
| 380 | Exhaust thermistor fault | Medium |
| 393 | Outdoor temperature sensor fault | Medium |
| 400 | Water pressure sensor communication fault | Medium |
| 430 | High or low system water pressure | High |
| 443 | Low water cut-off (LWCO) activated | High |
| 520 | Gas solenoid valve circuit – flame after valve close | Critical |
| 540 | High exhaust (flue gas) temperature | Critical |
| 610 | Combustion fan motor speed fault | High |
| 631 | DHW Recirculation Pump (Combi Only) | Low |
| 651 | Water Flow Control (Combi Only) | Medium |
| 661 | By-Pass (Combi Only) | Medium |
| 670 | 3-Way Valves (Combi Only) | Medium |
| 681 | Hot Water Supply Temperature Abnormality (Combi Only) | Medium |
| 700 | PC Board fault | High |
| 710 | Gas solenoid circuit – valve position mismatch | High |
| 720 | Flame rod fault | High |
| 763 | 0-10V external control input over-voltage | Medium |
| 831 | Indirect tank call running too long | Medium |
| 890 | Freeze condition detected | High |
| 999 | PC Board / software mismatch | High |
| E00 | Poor flame formation (flame sensed with burner off) | High |
| E02 | No flame formation (ignition failure) | High |
| E04 | Voltage interruption / error read-out interrupted | Medium |
| E05 | Adjustment error (listed in short reference) | Medium |
| E12 | High limit stat open | High |
| E14 | Supply sensor T1 fault | High |
| E18 | Maximum supply temperature exceeded | High |
| E19 | Maximum return temperature exceeded | High |
| E28 | Fan speed not reported back | High |
| E31 | Supply sensor T1 shorted | High |
| E32 | Return sensor T2 shorted | High |
| E36 | Supply sensor T1 open | High |
| E37 | Return sensor T2 open | High |
| E69 | No or incorrect display | Medium |
| E393 | Outdoor sensor harness disconnected | Medium |
| E430 | Low water pressure in the heating system | High |
| SW1-SW3 | PC board buttons (SW1, SW2, SW3) | Menu / mode display |
| A XX | De-aeration running | Normal status |
| Block 01 | External safety contact open | Medium |
| Block 05 | Outdoor sensor not connected | Low |
| Block 60 | Wrong minimum/maximum power parameter | Medium |
| Block 67 | Supply/return sensor difference with burner off | Medium |
| Block 85 | No water flow detected | Medium |
| COdE | Access code entry | Menu / mode display |
| Copy | Factory settings restored | Normal status |
| ECL | Reset complete (gas solenoid circuit) | Normal status |
| ERRO | Error chapter | Menu / mode display |
| End | Descaling complete | Menu / mode display |
| FFF | Maintenance performed marker | Low |
| FH | Forced High Fire Mode | Normal status |
| FILL | Water pressure low / system empty | Normal status |
| FL | Forced Low Fire Mode | Normal status |
| FUSE | 24 V fuse defective | High |
| Good | Good state (normal) | Normal status |
| Green button reset | Restore factory parameters | Menu / mode display |
| HIGH | Water pressure too high | Normal status |
| INFO | Information chapter | Menu / mode display |
| Ignition safety test | Test ionization lockout | Menu / mode display |
| LC | Lime scale detected on DHW side | Medium |
| P | Venturi reset: first screen | Menu / mode display |
| P XX | Water pressure read-out | Normal status |
| PARA | Parameter chapter | Menu / mode display |
| PCL | Venturi reset accepted | Normal status |
| Parameter mode | Parameter settings menu | Menu / mode display |
| Perf data | Performance data menu | Menu / mode display |
| SE | Secondary unit error (cascade) | Medium |
| SERV | Service chapter | Menu / mode display |
| SERVICE | Service due | Normal status |
| SS | Service Soon reminder | Low |
| STOP | Fill target reached | Normal status |
| StBY | Standby / exit to read-out | Normal status |
| Status 0 | No heat demand | Normal status |
| Status 1 | Fan pre/post purge | Normal status |
| Status 2 | Ignition phase | Normal status |
| Status 3 | Burner on, central heating | Normal status |
| Status 4 | Burner on, domestic hot water | Normal status |
| Status 5 | Fan check | Normal status |
| Status 6 | Burner off, demand pending | Normal status |
| Status 7 | Pump overrun, central heating | Normal status |
| Status 8 | Pump overrun, hot water | Normal status |
| Status 9 | Burner off, supply temperature too high | Normal status |
| Status A | Automatic de-aeration program | Normal status |
| Technical read-out | Technical read-out | Menu / mode display |
| dES | Descaling (automated flush) mode | Menu / mode display |
| rnS | Rinsing stage (descaling flush) | Menu / mode display |
Models covered
E110CRNE110CRPE50CRNE75CRNE75CRPIP060SIP090SIP120SIP150SIP175SIP199S
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.