Rinnai · Boiler

Block 60 Wrong minimum/maximum power parameter

Medium severity E-Combi (E50CRNE75CRN/E75CRPE110CRN/E110CRP)

What the control is telling you

Temporary block: the minimum or maximum power parameter is set to an invalid value.

Applies to: E50CRN; E75CRN; E75CRP; E110CRN; E110CRP

Likely causes

  • Parameter 3 or 43 set out of range

Test and repair steps

  1. Review the power parameters in PARA mode (3 and 43) against the factory values.
  2. If the cause is not clear, contact Rinnai (the manual says to call Rinnai).

Other codes on the same units

  • A XX De-aeration running
  • Block 01 External safety contact open
  • Block 05 Outdoor sensor not connected
  • Block 67 Supply/return sensor difference with burner off
  • Block 85 No water flow detected
  • COdE Access code entry
  • Copy Factory settings restored
  • ERRO Error chapter

Save it for the next call

Star this code in the HVACopedia app and keep the whole library on your phone for jobs with no signal.

Open the app

Source: Rinnai E-Combi Series Installation & Servicing Instructions (8U516009 V0116), p.71-72 (15.1, 15.2). Summarized in our own words; check the original manual for your model.

Homeowner looking at this code? See what it means for you and when to call a technician.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.