Rinnai · Boiler

Block 85 No water flow detected

Medium severity E-Combi (E50CRNE75CRN/E75CRPE110CRN/E110CRP)

What the control is telling you

Temporary block: the control cannot detect water flow. A de-aeration cycle starts; if flow is detected during the cycle, it ends and the burner is released.

Applies to: E50CRN; E75CRN; E75CRP; E110CRN; E110CRP

Likely causes

  • Air in the system
  • Secondary pump not hydraulically separated, causing pressure differences
  • Balancing valves set badly
  • Pump faulty or dirty
  • Dirty water pressure sensor or water filter
  • Pump wiring fault

Test and repair steps

  1. Check the system for air and bleed it.
  2. If a secondary pump is installed, confirm it is hydraulically separated.
  3. Check balancing valve settings.
  4. Check the pump runs and its wiring; clean it if dirty.
  5. Check the water pressure sensor and clean the return water filter.

Other codes on the same units

  • A XX De-aeration running
  • Block 01 External safety contact open
  • Block 05 Outdoor sensor not connected
  • Block 60 Wrong minimum/maximum power parameter
  • Block 67 Supply/return sensor difference with burner off
  • COdE Access code entry
  • Copy Factory settings restored
  • ERRO Error chapter

Save it for the next call

Star this code in the HVACopedia app and keep the whole library on your phone for jobs with no signal.

Open the app

Source: Rinnai E-Combi Series Installation & Servicing Instructions (8U516009 V0116), p.71-72 (15.1, 15.2). Summarized in our own words; check the original manual for your model.

Homeowner looking at this code? See what it means for you and when to call a technician.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.