Rinnai · Boiler

321 Outgoing Thermistor (Combi Only)

Medium severity I-Series Plus

What the control is telling you

Outgoing thermistor fault on the combi boiler.

Applies to: I-Series Plus combi boiler

Likely causes

  • Damaged sensor wiring
  • Scale on sensor
  • Sensor resistance out of range

Test and repair steps

  1. Check sensor wiring for damage.
  2. Clean any scale buildup from the sensor.
  3. Measure the resistance of the sensor.
  4. Replace the sensor if needed.

Other codes on the same units

  • 00-A Parameter menu entry
  • 021 Too Long DHW Continuous Operation
  • 60 Descaling countdown (minutes remaining)
  • 331 Heat Exchanger Thermistor (Combi Only)
  • 341 Inlet Thermistor (Combi Only)
  • 631 DHW Recirculation Pump (Combi Only)
  • 651 Water Flow Control (Combi Only)
  • 661 By-Pass (Combi Only)

Save it for the next call

Star this code in the HVACopedia app and keep the whole library on your phone for jobs with no signal.

Open the app

Source: Rinnai I-Series Plus IP060160C installation and operation manual, p. 114. Summarized in our own words; check the original manual for your model.

Homeowner looking at this code? See what it means for you and when to call a technician.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.