Rinnai · Boiler
FL Forced Low Fire Mode
What the display is showing
Controller shows FL when the boiler is in forced low fire test mode.
Applies to: I-Series Plus combi boiler
What to do
- Remove the front panel (two screws).
- Locate the PC board on the lower left side.
- Press and hold the right-side black button until FL shows.
- Press the right-side black button to return to normal operation.
Other codes on the same units
Save it for the next call
Star this code in the HVACopedia app and keep the whole library on your phone for jobs with no signal.
Source: Rinnai I-Series Plus IP060160C installation and operation manual, p. 118. Summarized in our own words; check the original manual for your model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.