Navien general error codes
115 codes with causes and test steps.
| Code | Meaning | Severity / type |
|---|---|---|
| 001 | Water leakage | High |
| 002 | Water outage | Medium |
| 003 | Water outage during CIP | Medium |
| 010 | High water pressure | Medium |
| 020 | Product flow path clogged | Medium |
| 021 | Regeneration line open | Medium |
| 022 | Regeneration line open | Medium |
| 023 | Bypass line clogged | Medium |
| 024 | Regeneration line clogged | Medium |
| 025 | Regeneration line clogged | Medium |
| 026 | Product water line clogged | Medium |
| 027 | Product water line clogged | Medium |
| 041 | Abnormal NDI module performance | Medium |
| 042 | Abnormal NDI module performance | Medium |
| 051 | Main CIP or TDS sensor relay | Medium |
| 052 | Regeneration line CIP | Medium |
| 060 | Flow sensor fault | Medium |
| 061 | Flow sensor fault | Medium |
| 062 | TDS sensor fault | Medium |
| 063 | TDS sensor fault | Medium |
| 064 | TDS sensor fault | Medium |
| 065 | Pressure sensor fault | Medium |
| 066 | Temperature sensor fault | Medium |
| 067 | Ambient air temperature sensor fault | Medium |
| 070 | Water connection | Medium |
| 071 | Abnormal faucet opening | Low |
| 072 | Abnormal close of the bypass valve | High |
| 073 | Abnormal close of the main valve | High |
| 074 | Abnormal open of the main valve | High |
| 075 | Abnormal open of the bypass valve | High |
| 076 | Abnormal close of the product water valve | High |
| 077 | Abnormal close of the regeneration valve | High |
| 078 | Abnormal close of the regeneration valve | High |
| 079 | Abnormal open of the regeneration valve | High |
| 080 | Abnormal open of the regeneration valve | High |
| 081 | Abnormal open of the product water valve | High |
| 082 | Abnormal open of the product water valve | High |
| 083 | Abnormal operation of CIP check | Medium |
| 084 | Abnormal operation of circulation pump check | Medium |
| 090 | Main valve electronics fault | High |
| 091 | Bypass valve electronics fault | High |
| 092 | Product water valve electronics fault | High |
| 093 | Product water valve electronics fault | High |
| 094 | Regeneration valve electronics fault | High |
| 095 | Regeneration valve electronics fault | High |
| 096 | Circulation valve electronics fault | High |
| 097 | Circulation valve electronics fault | High |
| 098 | CIP pump electronics fault | High |
| 099 | Circulation pump valve electronics fault | High |
| 100 | Anti-freezing valve electronics fault | High |
| 105 | Abnormal RTC | Medium |
| 106 | Abnormal panel key | Low |
| 107 | Abnormal EEPROM | Medium |
| 110 | Power board overheat | High |
| 111 | Over voltage at DC-Link | High |
| 112 | Over current at converter | High |
| 113 | Over current at module | High |
| 114 | Over current at module | High |
| 115 | IGBT error | High |
| 116 | Over voltage inverter | High |
| 117 | Under voltage inverter | High |
| 118 | Over frequency inverter | High |
| 119 | Under frequency inverter | High |
| 120 | AD offset error | High |
| 122 | Heat sink sensor error | Medium |
| 123 | Fan error | Medium |
| 124 | Security-chip error | High |
| 130 | Power board communication error | High |
| 615 | Abnormal memory | Medium |
| E001 | Leak detected | High |
| E002 | Drain line flow error | Medium |
| E003 | Drain line flow error | Medium |
| E010 | High inlet water pressure | Medium |
| E020 | Bypass or pressure sensor error | Medium |
| E021 | Regeneration line #1 open error (left) | Medium |
| E022 | Regeneration line #2 open error (right) | Medium |
| E023 | Bypass solenoid valve error | Medium |
| E024 | Regeneration line #1 blockage error (left) | Medium |
| E025 | Regeneration line #2 blockage error (right) | Medium |
| E026 | Drain line error (main solenoid path) | Medium |
| E027 | Drain line error (main solenoid path) | Medium |
| E041 | TDS sensor error | Medium |
| E042 | TDS sensor error | Medium |
| E051 | CIP dosing or circulation error | Medium |
| E060 - E067 | Individual sensor errors | Medium |
| E070 | Install Check Mode drain line error | Medium |
| E070 - E084 | Install Check Mode errors | Medium |
| E071 | No water to drain line after faucet opened | Medium |
| E072 | Bypass valve fault | Medium |
| E073 | Main valve fault | Medium |
| E074 | Main valve and product water valve fault | Medium |
| E075 | Bypass valve fault | Medium |
| E076 | Product water valve fault | Medium |
| E077 | Left drain regeneration line closed | Medium |
| E078 | Right drain regeneration line closed | Medium |
| E079 | Left drain regeneration line opening | Medium |
| E080 | Right drain regeneration line opening | Medium |
| E081 | Left product water solenoid valve opening | Medium |
| E082 | Right product water solenoid valve opening | Medium |
| E083 | CIP dosing pump fault | Medium |
| E084 | Circulation pump fault | Medium |
| E090 - E100 | Individual sensor or pump fault | Medium |
| E105 | PCB fault | Medium |
| E106 | PCB or harness fault | Medium |
| E107 | PCB or harness fault | Medium |
| E110 | Power unit overheating | High |
| E111 - E115 | Temporary power unit fault | Medium |
| E116 | Input voltage high | Medium |
| E117 | Input voltage low | Medium |
| E118 | Input frequency high | Medium |
| E119 | Input frequency low | Medium |
| E122 | Heat sink sensor fault | Medium |
| E123 | Fan fault | Medium |
| E124 | Power assembly fault | Medium |
| E130 | Main panel to power board communication fault | Medium |
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.