E022 Regeneration line #2 open error (right)
What the control is telling you
Opening error in regeneration line #2 (right drain line).
Applies to: WEC600
Likely causes
- Regeneration solenoid valve or harness faulty
- Flow switch or harness faulty
- Inlet pressure outside allowable range
Test and repair steps
- Turn off the unit.
- Check whether water is supplied to the drain line.
- If water is supplied, check the inlet water pressure is within the allowable range.
- If pressure is in range, replace the drain line flow switch or its harness.
- If water is not supplied to the drain line, replace the regeneration solenoid valve or its harness.
Other codes on the same units
- E003 Drain line flow error
- E010 High inlet water pressure
- E020 Bypass or pressure sensor error
- E021 Regeneration line #1 open error (left)
- E023 Bypass solenoid valve error
- E024 Regeneration line #1 blockage error (left)
- E025 Regeneration line #2 blockage error (right)
- E026 Drain line error (main solenoid path)
Save it for the next call
Star this code in the HVACopedia app and keep the whole library on your phone for jobs with no signal.
Source: Navien WEC service manual, p. 60. Summarized in our own words; check the original manual for your model.
Homeowner looking at this code? See what it means for you and when to call a technician.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.