Navien · General

E023 Bypass solenoid valve error

Medium severity WEC

What the control is telling you

Water flow through the bypass solenoid valve path is not correct.

Applies to: WEC600

Likely causes

  • Bypass solenoid valve or harness faulty
  • Inlet pressure outside allowable range
  • Pressure sensor or harness faulty

Test and repair steps

  1. Turn off the unit.
  2. Check whether water flows to the drain line when the faucet is opened.
  3. If water flows, check the inlet water pressure is within the allowable range, and replace the pressure sensor or its harness if it is.
  4. If water does not flow, replace the bypass solenoid valve or its harness.
  5. Note the manual's branch wording is ambiguous; confirm the flow path before replacing parts.

Other codes on the same units

  • E010 High inlet water pressure
  • E020 Bypass or pressure sensor error
  • E021 Regeneration line #1 open error (left)
  • E022 Regeneration line #2 open error (right)
  • E024 Regeneration line #1 blockage error (left)
  • E025 Regeneration line #2 blockage error (right)
  • E026 Drain line error (main solenoid path)
  • E027 Drain line error (main solenoid path)

Save it for the next call

Star this code in the HVACopedia app and keep the whole library on your phone for jobs with no signal.

Open the app

Source: Navien WEC service manual, p. 61. Summarized in our own words; check the original manual for your model.

Homeowner looking at this code? See what it means for you and when to call a technician.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.