E027 Drain line error (main solenoid path)
What the control is telling you
Water is not reaching the drain line as expected. Flowchart is shared with E026.
Applies to: WEC600
Likely causes
- Main solenoid valve or harness faulty
- Product water solenoid valve or harness faulty
- Bypass valve or harness faulty
Test and repair steps
- Enter Installer Setting Mode option 03 (Service Mode).
- Check whether water is supplied to the drain line; if not, replace the main solenoid valve or its harness.
- Replace the corresponding line's product water solenoid valve or its harness.
- If water does not flow to the drain line when the faucet is opened, replace the bypass valve or its harness.
- Close the faucet and reset the error manually.
Other codes on the same units
Save it for the next call
Star this code in the HVACopedia app and keep the whole library on your phone for jobs with no signal.
Source: Navien WEC service manual, p. 62. Summarized in our own words; check the original manual for your model.
Homeowner looking at this code? See what it means for you and when to call a technician.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.