Navien · General

E026 Drain line error (main solenoid path)

Medium severity WEC

What the control is telling you

Water is not reaching the drain line as expected. Section header is E026/E027.

Applies to: WEC600

Likely causes

  • Main solenoid valve or harness faulty
  • Product water solenoid valve or harness faulty
  • Bypass valve or harness faulty

Test and repair steps

  1. Enter Installer Setting Mode option 03 (Service Mode).
  2. Check whether water is supplied to the drain line; if not, replace the main solenoid valve or its harness.
  3. Replace the corresponding line's product water solenoid valve or its harness.
  4. If water does not flow to the drain line when the faucet is opened, replace the bypass valve or its harness.
  5. Close the faucet and reset the error manually.

Other codes on the same units

  • E022 Regeneration line #2 open error (right)
  • E023 Bypass solenoid valve error
  • E024 Regeneration line #1 blockage error (left)
  • E025 Regeneration line #2 blockage error (right)
  • E027 Drain line error (main solenoid path)
  • E041 TDS sensor error
  • E042 TDS sensor error
  • E051 CIP dosing or circulation error

Save it for the next call

Star this code in the HVACopedia app and keep the whole library on your phone for jobs with no signal.

Open the app

Source: Navien WEC service manual, p. 62. Summarized in our own words; check the original manual for your model.

Homeowner looking at this code? See what it means for you and when to call a technician.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.