Navien · General

E042 TDS sensor error

Medium severity WEC

What the control is telling you

TDS sensor reading fault. Flowchart is shared with E041.

Applies to: WEC600

Likely causes

  • TDS sensor or module fault

Test and repair steps

  1. Reset the error manually and enter Installer Setting Mode option 08 (Test CIP).
  2. If the error occurs again, replace the module.
  3. Monitor the inlet and outlet TDS over a week using NaviLink.
  4. If inlet TDS is continuously higher than outlet TDS, replace all 3 TDS sensors.

Other codes on the same units

  • E025 Regeneration line #2 blockage error (right)
  • E026 Drain line error (main solenoid path)
  • E027 Drain line error (main solenoid path)
  • E041 TDS sensor error
  • E051 CIP dosing or circulation error
  • E060 - E067 Individual sensor errors
  • E070 Install Check Mode drain line error
  • E070 - E084 Install Check Mode errors

Save it for the next call

Star this code in the HVACopedia app and keep the whole library on your phone for jobs with no signal.

Open the app

Source: Navien WEC service manual, p. 62. Summarized in our own words; check the original manual for your model.

Homeowner looking at this code? See what it means for you and when to call a technician.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.