E070 Install Check Mode drain line error

Medium severity WEC

What the control is telling you

Error during Install Check Mode. The faucet must be open at a flow rate above 4 LPM during this check.

Applies to: WEC600

Likely causes

  • House water supply not available
  • Drain line regeneration solenoid valve or harness faulty
  • Main solenoid valve or harness faulty
  • Drain line flow switch or harness faulty
  • Inlet pressure outside allowable range

Test and repair steps

  1. Open the faucet to a flow rate above 4 LPM.
  2. Wait until water is supplied, and check whether the error resets automatically after 30 seconds.
  3. Check that the customer's house is supplied with water and that water reaches the drain line.
  4. If either drain line is not working, replace its regeneration solenoid valve or harness.
  5. If both drain lines are not working, replace the main solenoid valve or harness.
  6. If the error occurs again after replacing the main solenoid valve, replace the regeneration solenoid valves or harnesses.
  7. Check that inlet water pressure is within the allowable range.
  8. If the error occurs again, replace the drain line flow switch or harness.

Other codes on the same units

  • E025 Regeneration line #2 blockage error (right)
  • E026 Drain line error (main solenoid path)
  • E027 Drain line error (main solenoid path)
  • E041 TDS sensor error
  • E042 TDS sensor error
  • E051 CIP dosing or circulation error
  • E060 - E067 Individual sensor errors
  • E070 - E084 Install Check Mode errors

Save it for the next call

Star this code in the HVACopedia app and keep the whole library on your phone for jobs with no signal.

Open the app

Source: Navien WEC service manual, p. 64. Summarized in our own words; check the original manual for your model.

Homeowner looking at this code? See what it means for you and when to call a technician.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.