Navien · General

E110 Power unit overheating

High severity WEC Series

What the control is telling you

Power heat sink overheating fault.

Applies to: WEC600

Likely causes

  • Overheating from the operating environment
  • Faulty power heat sink sensors or harnesses
  • Faulty power assembly

Test and repair steps

  1. Reset the error and monitor the surroundings and the product to prevent overheating.
  2. Replace the 2 power heat sink sensors or their harnesses.
  3. If the error returns, replace the power assembly.

Other codes on the same units

Save it for the next call

Star this code in the HVACopedia app and keep the whole library on your phone for jobs with no signal.

Open the app

Source: Navien WEC service manual, p. 69. Summarized in our own words; check the original manual for your model.

Homeowner looking at this code? See what it means for you and when to call a technician.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.