E090 - E100 Individual sensor or pump fault

Medium severity WEC Series

What the control is telling you

Fault on one of the individual sensors or pumps in the E090 to E100 group.

Applies to: WEC600

Likely causes

  • Faulty part
  • Faulty harness
  • Faulty PCB

Test and repair steps

  1. Remove the harness from the part and reconnect it to a working part, then reset the error.
  2. If the error stops, replace the part with a working one.
  3. If the error returns, replace the harness and reset the error.
  4. If the error still returns, replace the PCB and reset the error.

Other codes on the same units

  • E081 Left product water solenoid valve opening
  • E082 Right product water solenoid valve opening
  • E083 CIP dosing pump fault
  • E084 Circulation pump fault
  • E105 PCB fault
  • E106 PCB or harness fault
  • E107 PCB or harness fault
  • E110 Power unit overheating

Save it for the next call

Star this code in the HVACopedia app and keep the whole library on your phone for jobs with no signal.

Open the app

Source: Navien WEC service manual, p. 69. Summarized in our own words; check the original manual for your model.

Homeowner looking at this code? See what it means for you and when to call a technician.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.