Navien · General

E078 Right drain regeneration line closed

Medium severity WEC Series

What the control is telling you

Right drain regeneration line is closed when it should be open.

Applies to: WEC600

Likely causes

  • Faulty right drain line flow switch or harness
  • Faulty right drain line regeneration solenoid valve or harness

Test and repair steps

  1. Check whether water is supplied to the right drain line.
  2. If the manual's yes branch applies, replace the right drain line flow switch or its harness.
  3. If the no branch applies, replace the right drain line regeneration solenoid valve or its harness.
  4. Reset the error and confirm operation.

Other codes on the same units

  • E074 Main valve and product water valve fault
  • E075 Bypass valve fault
  • E076 Product water valve fault
  • E077 Left drain regeneration line closed
  • E079 Left drain regeneration line opening
  • E080 Right drain regeneration line opening
  • E081 Left product water solenoid valve opening
  • E082 Right product water solenoid valve opening

Save it for the next call

Star this code in the HVACopedia app and keep the whole library on your phone for jobs with no signal.

Open the app

Source: Navien WEC service manual, p. 66. Summarized in our own words; check the original manual for your model.

Homeowner looking at this code? See what it means for you and when to call a technician.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.