Navien · General

E079 Left drain regeneration line opening

Medium severity WEC Series

What the control is telling you

Left drain regeneration line opening fault. The manual's text refers to this as E022 in the description, which appears to be a typo.

Applies to: WEC600

Likely causes

  • Faulty left drain line regeneration solenoid valve or harness
  • Inlet water pressure out of range
  • Faulty left drain line flow switch or harness

Test and repair steps

  1. Check whether water is supplied to the left drain line.
  2. If the yes branch applies, replace the left drain line regeneration solenoid valve or its harness.
  3. If the no branch applies, check that inlet water pressure is within the allowable range.
  4. If pressure is correct, replace the left drain line flow switch or its harness.
  5. Reset the error.

Other codes on the same units

  • E075 Bypass valve fault
  • E076 Product water valve fault
  • E077 Left drain regeneration line closed
  • E078 Right drain regeneration line closed
  • E080 Right drain regeneration line opening
  • E081 Left product water solenoid valve opening
  • E082 Right product water solenoid valve opening
  • E083 CIP dosing pump fault

Save it for the next call

Star this code in the HVACopedia app and keep the whole library on your phone for jobs with no signal.

Open the app

Source: Navien WEC service manual, p. 67. Summarized in our own words; check the original manual for your model.

Homeowner looking at this code? See what it means for you and when to call a technician.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.