Navien · General

021 Regeneration line open

Medium severity WEC Series

What the control is telling you

Regeneration solenoid valve open fault (valve 1).

Applies to: WEC600

Likely causes

  • Regeneration solenoid valve

Test and repair steps

  1. Check inlet pressure is 36.3-74 psi (250-510 kPa).
  2. Clear with ErSt, check drain outlet in Standby, then recheck.

Other codes on the same units

  • 002 Water outage
  • 003 Water outage during CIP
  • 010 High water pressure
  • 020 Product flow path clogged
  • 022 Regeneration line open
  • 023 Bypass line clogged
  • 024 Regeneration line clogged
  • 025 Regeneration line clogged

Save it for the next call

Star this code in the HVACopedia app and keep the whole library on your phone for jobs with no signal.

Open the app

Source: Navien WEC service manual, p. 53. Summarized in our own words; check the original manual for your model.

Homeowner looking at this code? See what it means for you and when to call a technician.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.