Navien · General

E002 Drain line flow error

Medium severity WEC

What the control is telling you

Water is not flowing correctly to a drain line during operation.

Applies to: WEC600

Likely causes

  • House water supply not available
  • Drain line regeneration solenoid valve or harness faulty
  • Main solenoid valve or harness faulty
  • Drain line flow switch or harness faulty
  • Inlet water pressure outside allowable range

Test and repair steps

  1. Wait until water is supplied, and check whether the error resets automatically after 30 seconds.
  2. Check that the customer's house is supplied with water.
  3. Check that water is supplied to the drain line.
  4. If either drain line is not working, replace its regeneration solenoid valve or harness.
  5. If both drain lines are not working, replace the main solenoid valve or harness.
  6. If the error occurs again after replacing the main solenoid valve, replace the regeneration solenoid valve or harness.
  7. Check that inlet water pressure is within the allowable range.
  8. If the error occurs again, replace the drain line flow switch or harness.

Other codes on the same units

  • 123 Fan error
  • 124 Security-chip error
  • 130 Power board communication error
  • E001 Leak detected
  • E003 Drain line flow error
  • E010 High inlet water pressure
  • E020 Bypass or pressure sensor error
  • E021 Regeneration line #1 open error (left)

Save it for the next call

Star this code in the HVACopedia app and keep the whole library on your phone for jobs with no signal.

Open the app

Source: Navien WEC service manual, p. 59. Summarized in our own words; check the original manual for your model.

Homeowner looking at this code? See what it means for you and when to call a technician.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.