Navien · General

E123 Fan fault

Medium severity WEC Series

What the control is telling you

Fan circuit fault.

Applies to: WEC600

Likely causes

  • Faulty fan or harness
  • Faulty power assembly
  • Faulty PCB

Test and repair steps

  1. Replace the fan or its harness.
  2. If the error returns, replace the power assembly.
  3. If it still returns, replace the PCB.

Other codes on the same units

  • E111 - E115 Temporary power unit fault
  • E116 Input voltage high
  • E117 Input voltage low
  • E118 Input frequency high
  • E119 Input frequency low
  • E122 Heat sink sensor fault
  • E124 Power assembly fault
  • E130 Main panel to power board communication fault

Save it for the next call

Star this code in the HVACopedia app and keep the whole library on your phone for jobs with no signal.

Open the app

Source: Navien WEC service manual, p. 72. Summarized in our own words; check the original manual for your model.

Homeowner looking at this code? See what it means for you and when to call a technician.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.