Trane furnace error codes
30 codes with causes and test steps, plus 7 settings tables.
| Code | Meaning | Severity |
|---|---|---|
| E01 | Furnace control internal failure | High |
| E2.1 | Ignition retries exceeded - flame never proven (1 hour lockout) | High |
| E2.2 | Flame recycles exceeded - flame lost after lighting (1 hour lockout) | High |
| E2.3 | 1st stage gas valve not powered when it should be (10 times) | High |
| E3.1 | 1st stage pressure switch (PS1) closed when it should be open | Medium |
| E3.2 | 1st stage pressure switch (PS1) open when it should be closed | Medium |
| E3.3 | 2nd stage pressure switch (PS2) closed when it should be open | Medium |
| E3.4 | 2nd stage pressure switch (PS2) open when it should be closed | Medium |
| E04 | Open limit (main limit, rollout or reverse airflow) | High |
| E4.0 | Main high limit open | High |
| E4.1 | Reverse airflow limit open | High |
| E4.2 | Flame rollout switch open | Critical |
| E05 | Flame sensed when no flame should be present | Critical |
| E6.1 | 120 V polarity reversed | Medium |
| E6.2 | Ground not detected | Medium |
| E6.3 | Igniter open or igniter relay fault | High |
| E7.1 | 1st stage gas valve (MVL) powered with no call | Critical |
| E7.2 | Redundant relay (HLO output) on with no call | Critical |
| E08 | Low flame signal (still running) | Low |
| E11 | Gas valve relay / valve circuit fault | High |
| E12 | Control fuse open | Medium |
| E13 | Blower motor size / OEM ID mismatch | Medium |
| E14 | Configuration file error | Medium |
| E17 | Blower motor communication error | High |
| E23 | Menu data not received by combustion micro (CCM) | Medium |
| E24 | Internal communication error between ACM and CCM | Medium |
| E25 | Orientation sensor out of range | Low |
| E26 | Return static pressure sensor out of range or not connected | Low |
| E27 | Return air thermistor out of range or not connected | Low |
| E28 | Supply air thermistor out of range or not connected | Low |
Settings and specs
Clearance to combustibles
Clearances · Trane S8V2
| Cabinet width | Vertical sides / top | Horizontal sides / top |
|---|---|---|
| 14.5 in. | 0 / 1 in. | 1 / 2 in. |
| 17.5 in. | 0 / 1 in. | 1 / 2 in. |
| 21.0 in. | 0 / 1 in. | 1 / 3 in. |
| 24.5 in. | 0 / 1 in. | 1 / 5 in. |
- 24 in. front service access.
- 3 in. in front of the combustion air openings.
- Downflow on combustible floor without coil needs BAYBASE205.
- Garage: burners and igniter at least 18 in. above floor.
Source: Trane FNR-SVX003A-EN (S8V2) - Table 5
Return filter size by cabinet width
Filters · Trane S8V2
| Cabinet width | Filter |
|---|---|
| 14-1/2 in. | 1 - 14 x 25 x 1 in. |
| 17-1/2 in. | 1 - 16 x 25 x 1 in. |
| 21 in. | 1 - 20 x 25 x 1 in. |
| 24-1/2 in. | 1 - 24 x 25 x 1 in. |
- Filters are field supplied and mounted outside the cabinet.
- Over 1600 CFM upflow: return on both sides, one side plus bottom, or bottom only.
Source: Trane FNR-SVX003A-EN (S8V2) - Table 30
Return filter size by cabinet width
Filters · Trane S8B1, Trane S8X1, Trane S8X2
| Cabinet width | Filter |
|---|---|
| 14-1/2 in. | 1 - 14 x 25 x 1 in. |
| 17-1/2 in. | 1 - 16 x 25 x 1 in. |
| 21 in. | 1 - 20 x 25 x 1 in. |
| 24-1/2 in. | 1 - 24 x 25 x 1 in. |
- Filters are field supplied and mounted outside the cabinet.
- Over 1600 CFM upflow: return on both sides, one side plus bottom, or bottom only.
Source: Trane 18-CE14D1-1A-EN (S8B1/S8X1/S8X2) - Return Air Filters
Return filter size - upflow and downflow
Filters · Trane S9X1, Trane S9X2, Trane S9B1
| Cabinet width | Upflow | Downflow |
|---|---|---|
| 17-1/2 in. | 1 - 16 x 25 x 1 in. | 2 - 14 x 20 x 1 in. |
| 21 in. | 1 - 20 x 25 x 1 in. | 2 - 16 x 20 x 1 in. |
| 24-1/2 in. | 1 - 24 x 25 x 1 in. | 2 - 16 x 20 x 1 in. |
- Field supplied, installed outside the cabinet.
- Upflow over 1600 CFM needs two returns or a bottom return.
Source: Trane 18-CE12D1-1D-EN (S9X1/S9X2/S9B1) - Return Air Filters
Clearance to combustibles
Clearances · Trane S9X1, Trane S9X2, Trane S9B1
| Position | Sides | Back | Top | Front / bottom / flue |
|---|---|---|---|---|
| Upright closet | 0 in. | 1 in. | 1 in. | 0 in. |
| Horizontal closet / alcove | 0 in. | 1 in. | 1 in. | 0 in. |
| Horizontal, flue out left | 0 in. | 1 in. | 1 in. | 0 in. |
- 24 in. front clearance recommended for service.
- Furnace must sit level (slight tilt left/forward allowed) so condensate drains.
Source: Trane 18-CE12D1-1D-EN (S9X1/S9X2/S9B1) - Locations and Clearances
Return filter size - upflow and downflow
Filters · Trane S9V2
| Cabinet width | Upflow | Downflow |
|---|---|---|
| 17-1/2 in. | 1 - 16 x 25 x 1 in. | 2 - 14 x 20 x 1 in. |
| 21 in. | 1 - 20 x 25 x 1 in. | 2 - 16 x 20 x 1 in. |
| 24-1/2 in. | 1 - 24 x 25 x 1 in. | 2 - 16 x 20 x 1 in. |
- Field supplied, installed outside the cabinet.
- Upflow over 1600 CFM needs two returns or a bottom return.
Source: Trane 18-CE19D1-1B-EN (S9V2) - Return Air Filters
Clearance to combustibles
Clearances · Trane S9V2
| Position | Sides | Back | Top | Front / bottom / flue |
|---|---|---|---|---|
| Upright closet | 0 in. | 1 in. | 1 in. | 0 in. |
| Horizontal closet / alcove | 0 in. | 1 in. | 1 in. | 0 in. |
| Horizontal, flue out left | 0 in. | 1 in. | 1 in. | 0 in. |
- 24 in. front clearance recommended for service.
- Furnace must sit level (slight tilt left/forward allowed) so condensate drains.
Source: Trane 18-CE19D1-1B-EN (S9V2) - Locations and Clearances
Models covered
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.