Trane · Furnace

tP1 to tP9 Blower tap in use

Normal status Trane S8B1Trane S8X1Trane S8X2

What the display is showing

On S8B1, S8X1 and S8X2 the display alternates between the mode and the blower tap number (tP1 to tP9) in use for that call, for example tP3 for first-stage or tP7 for second-stage speed.

Applies to: S8B1, S8X1, S8X2

Settings for these units

Return filter size by cabinet width · Trane S8B1, Trane S8X1, Trane S8X2

Cabinet widthFilter
14-1/2 in.1 - 14 x 25 x 1 in.
17-1/2 in.1 - 16 x 25 x 1 in.
21 in.1 - 20 x 25 x 1 in.
24-1/2 in.1 - 24 x 25 x 1 in.

Filters are field supplied and mounted outside the cabinet.

Over 1600 CFM upflow: return on both sides, one side plus bottom, or bottom only.

Models that show this code

25 models in Trane S8B1, Trane S8X1, Trane S8X2

S8B1A026M2PSABS8B1A040M3PSABS8B1B040M2PSABS8B1B060M3PSABS8B1B060M4PSABS8B1B080M4PSABS8B1C080M5PSABS8B1C100M5PSABS8B1D120M5PSABS8X1A026M2PSABS8X1A040M3PSABS8X1B040M2PSABS8X1B060M3PSABS8X1B060M4PSABS8X1B080M4PSABS8X1C080M5PSABS8X1C100M5PSABS8X1D120M5PSABS8X2A040M3PSABS8X2B060M3PSABS8X2B060M4PSABS8X2B080M4PSABS8X2C080M5PSABS8X2C100M5PSABS8X2D120M5PSAB

Other codes on the same units

  • HP1 Heat pump, stage 1 demand
  • HP2 Heat pump, stage 2 demand
  • Ht1 Gas heat, stage 1 demand
  • Ht2 Gas heat, stage 2 demand
  • L6F Last 6 faults menu
  • --- Faults cleared confirmation
  • CoF Continuous fan demand
  • Cr Control code release number

Save it for the next call

Star this code in the HVACopedia app and keep the whole library on your phone for jobs with no signal.

Open the app

Source: Trane S8B1/S8X1/S8X2 installation 18-CE14D1-1A-EN, System Status Menu and Sequence of Operation, p.57 and p.60-61. Summarized in our own words; check the original manual for your model.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.