Trane · Furnace

CoF Continuous fan demand

Normal status Trane S8V2Trane S8B1Trane S8X1Trane S8X2Trane S9V2

What the display is showing

Display for a continuous-fan call (G only). Also read on a communicating system when the furnace runs the blower for cooling or heat pump operation.

Applies to: S8V2, S8B1, S8X1, S8X2 and S9V2

Settings for these units

Clearance to combustibles · Trane S8V2

Cabinet widthVertical sides / topHorizontal sides / top
14.5 in.0 / 1 in.1 / 2 in.
17.5 in.0 / 1 in.1 / 2 in.
21.0 in.0 / 1 in.1 / 3 in.
24.5 in.0 / 1 in.1 / 5 in.

24 in. front service access.

3 in. in front of the combustion air openings.

Return filter size by cabinet width · Trane S8V2

Cabinet widthFilter
14-1/2 in.1 - 14 x 25 x 1 in.
17-1/2 in.1 - 16 x 25 x 1 in.
21 in.1 - 20 x 25 x 1 in.
24-1/2 in.1 - 24 x 25 x 1 in.

Filters are field supplied and mounted outside the cabinet.

Over 1600 CFM upflow: return on both sides, one side plus bottom, or bottom only.

Models that show this code

44 models in Trane S8V2, Trane S8B1, Trane S8X1, Trane S8X2, Trane S9V2

S8B1A026M2PSABS8B1A040M3PSABS8B1B040M2PSABS8B1B060M3PSABS8B1B060M4PSABS8B1B080M4PSABS8B1C080M5PSABS8B1C100M5PSABS8B1D120M5PSABS8V2A040M3PCBS8V2A040M3PDS8V2B060M4PCBS8V2B060M4PDS8V2B080M4PCBS8V2B080M4PDS8V2C080M5PCBS8V2C080M5PDS8V2C100M5PCBS8V2C100M5PDS8V2D120M5PCBS8V2D120M5PDS8X1A026M2PSABS8X1A040M3PSABS8X1B040M2PSABS8X1B060M3PSABS8X1B060M4PSABS8X1B080M4PSABS8X1C080M5PSABS8X1C100M5PSABS8X1D120M5PSABS8X2A040M3PSABS8X2B060M3PSABS8X2B060M4PSABS8X2B080M4PSABS8X2C080M5PSABS8X2C100M5PSABS8X2D120M5PSABS9V2B040U3VSACS9V2B060U3VSACS9V2B080D4VSACS9V2B080U4VSACS9V2C100D4VSACS9V2C100U4VSACS9V2D120U5VSAC

Other codes on the same units

  • Ht2 Gas heat, stage 2 demand
  • L6F Last 6 faults menu
  • tP1 to tP9 Blower tap in use
  • --- Faults cleared confirmation
  • ARF Calculated airflow readout (cfm x 10)
  • Both LEDs flashing together Bluetooth pairing in progress
  • Cr Control code release number
  • FD Factory default reset done

Save it for the next call

Star this code in the HVACopedia app and keep the whole library on your phone for jobs with no signal.

Open the app

Source: Trane S8V2 installation FNR-SVX003A-EN, Figure 73, p.58; Trane S8B1/S8X1/S8X2 installation 18-CE14D1-1A-EN, System Status Menu, p.57; S9V2 installation 18-CE19D1-1B-EN wiring note. Summarized in our own words; check the original manual for your model.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.