Trane · Furnace
L6F Last 6 faults menu
What the display is showing
Menu that replays the six most recent faults. Faults can be cleared from inside it.
Applies to: S8V2, S8B1, S8X1, S8X2
What to do
- Press Menu until L6F appears.
- Press Option to enter and step through the faults.
- To clear inside the menu hold Option for at least 5 seconds, release, and three dashes appear three times.
Settings for these units
Clearance to combustibles · Trane S8V2
| Cabinet width | Vertical sides / top | Horizontal sides / top |
|---|---|---|
| 14.5 in. | 0 / 1 in. | 1 / 2 in. |
| 17.5 in. | 0 / 1 in. | 1 / 2 in. |
| 21.0 in. | 0 / 1 in. | 1 / 3 in. |
| 24.5 in. | 0 / 1 in. | 1 / 5 in. |
24 in. front service access.
3 in. in front of the combustion air openings.
Return filter size by cabinet width · Trane S8V2
| Cabinet width | Filter |
|---|---|
| 14-1/2 in. | 1 - 14 x 25 x 1 in. |
| 17-1/2 in. | 1 - 16 x 25 x 1 in. |
| 21 in. | 1 - 20 x 25 x 1 in. |
| 24-1/2 in. | 1 - 24 x 25 x 1 in. |
Filters are field supplied and mounted outside the cabinet.
Over 1600 CFM upflow: return on both sides, one side plus bottom, or bottom only.
- Return filter size by cabinet width · Trane S8B1, Trane S8X1, Trane S8X2
Models that show this code
37 models in Trane S8V2, Trane S8B1, Trane S8X1, Trane S8X2
Other codes on the same units
- HP1 Heat pump, stage 1 demand
- HP2 Heat pump, stage 2 demand
- Ht1 Gas heat, stage 1 demand
- Ht2 Gas heat, stage 2 demand
- tP1 to tP9 Blower tap in use
- --- Faults cleared confirmation
- ARF Calculated airflow readout (cfm x 10)
- Both LEDs flashing together Bluetooth pairing in progress
Save it for the next call
Star this code in the HVACopedia app and keep the whole library on your phone for jobs with no signal.
Source: Trane S8V2 installation FNR-SVX003A-EN, Table 36 and Fault Code Recovery, p.59-60; Trane S8B1/S8X1/S8X2 installation 18-CE14D1-1A-EN, Display Codes and Fault Code Recovery, p.58-59. Summarized in our own words; check the original manual for your model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.