Trane · Furnace
HP2 Heat pump, stage 2 demand
What the display is showing
Display for a second-stage heat pump call.
Applies to: S8V2 and S8X2
Settings for these units
Clearance to combustibles · Trane S8V2
| Cabinet width | Vertical sides / top | Horizontal sides / top |
|---|---|---|
| 14.5 in. | 0 / 1 in. | 1 / 2 in. |
| 17.5 in. | 0 / 1 in. | 1 / 2 in. |
| 21.0 in. | 0 / 1 in. | 1 / 3 in. |
| 24.5 in. | 0 / 1 in. | 1 / 5 in. |
24 in. front service access.
3 in. in front of the combustion air openings.
Return filter size by cabinet width · Trane S8V2
| Cabinet width | Filter |
|---|---|
| 14-1/2 in. | 1 - 14 x 25 x 1 in. |
| 17-1/2 in. | 1 - 16 x 25 x 1 in. |
| 21 in. | 1 - 20 x 25 x 1 in. |
| 24-1/2 in. | 1 - 24 x 25 x 1 in. |
Filters are field supplied and mounted outside the cabinet.
Over 1600 CFM upflow: return on both sides, one side plus bottom, or bottom only.
- Return filter size by cabinet width · Trane S8B1, Trane S8X1, Trane S8X2
Models that show this code
19 models in Trane S8V2, Trane S8X2
Other codes on the same units
- E26 Return static pressure sensor out of range or not connected
- E27 Return air thermistor out of range or not connected
- E28 Supply air thermistor out of range or not connected
- HP1 Heat pump, stage 1 demand
- Ht1 Gas heat, stage 1 demand
- Ht2 Gas heat, stage 2 demand
- L6F Last 6 faults menu
- tP1 to tP9 Blower tap in use
Sequence of operation
What the unit does around this code, step by step.
Save it for the next call
Star this code in the HVACopedia app and keep the whole library on your phone for jobs with no signal.
Source: Trane S8V2 installation FNR-SVX003A-EN, Figure 73, p.58; Trane S8B1/S8X1/S8X2 installation 18-CE14D1-1A-EN, Sequence of Operation, p.61. Summarized in our own words; check the original manual for your model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.