Trane · Furnace
E27 Return air thermistor out of range or not connected
What the control is telling you
The return temperature sensor in the blower harness is open/shorted or enabled but not connected. Furnace still runs.
Applies to: Trane S8V2 only
Likely causes
- Open or shorted thermistor
- Harness damage
- IFC input fault
Test and repair steps
- Warning: Turn off power before unplugging connectors or measuring resistance.
- Option disable return temperature in the diagnostics app or with Menu/Option (24 V mode only) to clear.
- Remove the 12-pin blower harness and read resistance between GY/56 and GY/57; compare to the thermistor table. Open or short: replace the blower harness.
- Unplug connector E21 (RET_T) and check about 3.2 VDC between its pins; under 3 VDC means replace the IFC.
Settings for these units
Clearance to combustibles · Trane S8V2
| Cabinet width | Vertical sides / top | Horizontal sides / top |
|---|---|---|
| 14.5 in. | 0 / 1 in. | 1 / 2 in. |
| 17.5 in. | 0 / 1 in. | 1 / 2 in. |
| 21.0 in. | 0 / 1 in. | 1 / 3 in. |
| 24.5 in. | 0 / 1 in. | 1 / 5 in. |
24 in. front service access.
3 in. in front of the combustion air openings.
Return filter size by cabinet width · Trane S8V2
| Cabinet width | Filter |
|---|---|
| 14-1/2 in. | 1 - 14 x 25 x 1 in. |
| 17-1/2 in. | 1 - 16 x 25 x 1 in. |
| 21 in. | 1 - 20 x 25 x 1 in. |
| 24-1/2 in. | 1 - 24 x 25 x 1 in. |
Filters are field supplied and mounted outside the cabinet.
Over 1600 CFM upflow: return on both sides, one side plus bottom, or bottom only.
Models that show this code
12 models in Trane S8V2
Other codes on the same units
- E23 Menu data not received by combustion micro (CCM)
- E24 Internal communication error between ACM and CCM
- E25 Orientation sensor out of range
- E26 Return static pressure sensor out of range or not connected
- E28 Supply air thermistor out of range or not connected
- HP1 Heat pump, stage 1 demand
- HP2 Heat pump, stage 2 demand
- Ht1 Gas heat, stage 1 demand
Save it for the next call
Star this code in the HVACopedia app and keep the whole library on your phone for jobs with no signal.
Source: Trane FNR-SVX003A-EN (S8V2 installer's guide) - section Integrated Furnace Control Display Codes, Table 37 Error codes; Trane FNR-SVX003A-EN (S8V2 installer's guide) - section Troubleshooting (flowcharts). Summarized in our own words; check the original manual for your model.
Homeowner looking at this code? See what it means for you and when to call a technician.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.