Trane · Furnace
Ht Gas heating (single-stage models)
What the display is showing
S8B1 and S8X1 show Ht during a gas heat call, alternating with the airflow tap readout. The legend lists Ht as the single-stage label for Ht1.
Applies to: S8B1 and S8X1
Settings for these units
Return filter size by cabinet width · Trane S8B1, Trane S8X1, Trane S8X2
| Cabinet width | Filter |
|---|---|
| 14-1/2 in. | 1 - 14 x 25 x 1 in. |
| 17-1/2 in. | 1 - 16 x 25 x 1 in. |
| 21 in. | 1 - 20 x 25 x 1 in. |
| 24-1/2 in. | 1 - 24 x 25 x 1 in. |
Filters are field supplied and mounted outside the cabinet.
Over 1600 CFM upflow: return on both sides, one side plus bottom, or bottom only.
Models that show this code
18 models in Trane S8B1, Trane S8X1
Other codes on the same units
Save it for the next call
Star this code in the HVACopedia app and keep the whole library on your phone for jobs with no signal.
Source: Trane S8B1/S8X1/S8X2 installation 18-CE14D1-1A-EN, System Status Menu, p.57; Sequence of Operation, p.60. Summarized in our own words; check the original manual for your model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.