Daikin mini-split error codes
31 codes (30 faults, 1 normal display and menu code).
| Code | Meaning | Severity / type |
|---|---|---|
| 00 | Normal (no fault stored) | Normal status |
| A1 | Indoor PCB abnormality | High |
| A5 | Freeze-up protection or heating peak-cut | Medium |
| A6 | Indoor fan motor (DC) abnormality | High |
| C4 | Indoor coil thermistor fault | Medium |
| C9 | Room temperature thermistor fault | Medium |
| E1 | Outdoor PCB abnormality | High |
| E3 | High pressure switch tripped | High |
| E5 | Compressor overload (OL) tripped | High |
| E6 | Compressor lock | Critical |
| E7 | Outdoor DC fan lock | High |
| E8 | Input overcurrent | High |
| F3 | Discharge pipe temperature too high | High |
| F6 | High pressure control in cooling | Medium |
| F8 | Compressor temperature abnormality shutdown | Critical |
| H0 | Compressor current sensor abnormality | High |
| H6 | Compressor position sensor abnormality (start failure) | High |
| H8 | Current transformer (CT) abnormality | High |
| H9 | Outdoor air thermistor fault | Medium |
| J3 | Discharge pipe thermistor fault | Medium |
| J6 | Outdoor coil thermistor fault | Medium |
| L3 | Electrical box temperature rise | Medium |
| L4 | Radiation fin temperature rise | High |
| L5 | Output overcurrent | High |
| P4 | Radiation fin thermistor fault | Medium |
| U0 | Refrigerant shortage | High |
| U2 | Low or high supply voltage detected | High |
| U4 | Indoor to outdoor signal error | High |
| U7 | Outdoor PCB internal communication error | High |
| EA | Four way valve abnormality | High |
| UA | Indoor and outdoor unit mismatch | High |
Models covered
FTX30WVJU9FTX36WVJU9RK30WMVJU9RK36WMVJU9RX09WMVJU9RX12WMVJU9RX30WMVJU9RX36WMVJU9RXL09WMVJU9RXL12WMVJU9
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.