Daikin heat pump error codes

65 codes with causes and test steps.

CodeMeaningSeverity / type
14Repeated high pressure faults (minor)Medium
16Repeated low pressure faults (minor)Medium
33Outdoor control board overheating (minor)Medium
52Repeated compressor faults (minor)Medium
53Repeated outdoor fan / board faults (minor)Medium
54Repeated low discharge superheat faults (minor)Medium
55Repeated high discharge temperature faults (minor)Medium
57Sweating on the board cooling loopMedium
E11System start-up test not doneLow
E12Control board memory errorHigh
E13Repeated high pressure faults (critical)High
E15Repeated low pressure faults (critical)High
E17Repeated compressor faults (critical)High
E18Control board may need replacing (outdoor fan drive)High
E19Repeated outdoor fan / board faults (critical)High
E20Outdoor EEV faultHigh
E21Repeated low discharge superheat faultsHigh
E22Repeated high discharge temperature faultsHigh
E23Discharge temperature sensor out of rangeMedium
E24High pressure switch openHigh
E25Outdoor air temperature sensor open or shortedMedium
E26Pressure sensor not respondingMedium
E27Outdoor coil defrost sensor out of rangeMedium
E28Outdoor coil temperature sensor out of rangeMedium
E29Liquid temperature sensor out of rangeMedium
E30Control board may need replacingHigh
E32Outdoor control board overheating (critical)High
E34High current detectedHigh
E35High current, possible short circuitCritical
E36Abnormal start-upHigh
E37Control board may need replacing (fan motor link)High
E38Compressor voltage problemHigh
E39Control board may need replacing (thermistor input)High
E40Compressor setup does not match the unitHigh
E41Low refrigerantHigh
E42Low supply voltageHigh
E43High supply voltageHigh
E44Outdoor temperature out of operating rangeLow
E47System verification test blocked by indoor heatLow
E49Charging mode blocked by indoor heatLow
E50Voltage problem on the control boardHigh
E51Communication problem seen by the outdoor boardHigh
E56Suction temperature sensor out of rangeMedium
E58Compressor overload (OL) sensor openHigh
Eb0Indoor airflow near zeroHigh
Eb9Indoor airflow below what is neededMedium
Ed0No shared data on the controlHigh
Ed1Bad shared or network dataHigh
Ed2Airflow needed is more than the indoor unit can giveMedium
Ed3Shared data does not match the hardwareMedium
Ed4Memory card data rejectedMedium
CoreSense 1CoreSense: yellow 1 flash, long run timeMedium
CoreSense 2CoreSense: 2 flashes, pressure trip (yellow alert / red lock)High
CoreSense 3CoreSense: 3 flashes, short cycling (yellow alert / red lock)Medium
CoreSense 4CoreSense: 4 flashes, locked rotor (yellow alert / red lock)High
CoreSense 5CoreSense: 5 flashes, moderate run trip (yellow alert / red lock)High
CoreSense 9CoreSense: red 9 flashes, PROT terminal over currentMedium
CoreSense TRIP+ALERT flashingCoreSense: TRIP and ALERT flashing togetherMedium
CoreSense solid redCoreSense: solid red TRIPHigh
CoreSense solid yellowCoreSense: solid yellow RUNLow
Green Rx LED 1 steady flashNetwork: no network foundMedium
Green Rx LED offNetwork: no power or no communicationMedium
Green Rx LED on solidNetwork: terminal 1 / 2 miswiredMedium
Red comm LED 1 flashNetwork: communications failureMedium
Red comm LED 2 flashesNetwork: out-of-box resetLow

Models covered

DH4SEA**10AADH4SQA**10AADH5SEA**10AADH6VS*181DH6VS*241DH6VS*301DH6VS*361DH6VS*421DH6VS*481DH6VS*601DH7VSA2410DH7VSA3610DH7VSA4210DH7VSA4810

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.