55 Repeated high discharge temperature faults (minor)
What the control is telling you
The thermostat shows 55; the board shows nothing. High discharge temperature several times, but the unit keeps running.
Applies to: DH6VS***1*A*, DH7VSA[24-48]10A* (FIT and Enhanced Capacity/High Efficiency FIT)
Likely causes
- Discharge thermistor bad, unplugged, off the pipe or in the wrong spot
- Low charge
- Too much refrigerant
- Bad compressor
Test and repair steps
- Kill power at the disconnect before opening the control box or touching wiring.
- Check the discharge thermistor resistance, plug and position on the pipe.
- Check the charge and adjust.
- Check the compressor.
Models that show this code
11 models in Daikin FIT DH6VS/DH7VSA
Other codes on the same units
- 33 Outdoor control board overheating (minor)
- 52 Repeated compressor faults (minor)
- 53 Repeated outdoor fan / board faults (minor)
- 54 Repeated low discharge superheat faults (minor)
- 57 Sweating on the board cooling loop
- E11 System start-up test not done
- E12 Control board memory error
- E13 Repeated high pressure faults (critical)
Save it for the next call
Star this code in the HVACopedia app and keep the whole library on your phone for jobs with no signal.
Source: Daikin 3P761829-1B FIT outdoor unit DC6VS/DH6VS/DC9VSA/DH7VSA installation & service reference, Troubleshooting table p.45 (printed page). Summarized in our own words; check the original manual for your model.
Homeowner looking at this code? See what it means for you and when to call a technician.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.