Daikin · Heat pump

E30 Control board may need replacing

High severity Daikin FIT DH6VS/DH7VSA

What the control is telling you

Thermostat shows 30, outdoor board display shows E30. The control flags a board problem.

Applies to: DH6VS***1*A*, DH7VSA[24-48]10A* (FIT and Enhanced Capacity/High Efficiency FIT)

Likely causes

  • Wiring to the control board unplugged
  • Bad control board
  • Electrical noise

Test and repair steps

  1. Kill power at the disconnect before opening the control box or touching wiring.
  2. Check all plugs and wiring on the control board.
  3. If the wiring is good and the code returns, replace the board.

Models that show this code

11 models in Daikin FIT DH6VS/DH7VSA

DH6VS*181DH6VS*241DH6VS*301DH6VS*361DH6VS*421DH6VS*481DH6VS*601DH7VSA2410DH7VSA3610DH7VSA4210DH7VSA4810

Other codes on the same units

  • E26 Pressure sensor not responding
  • E27 Outdoor coil defrost sensor out of range
  • E28 Outdoor coil temperature sensor out of range
  • E29 Liquid temperature sensor out of range
  • E32 Outdoor control board overheating (critical)
  • E34 High current detected
  • E35 High current, possible short circuit
  • E36 Abnormal start-up

Save it for the next call

Star this code in the HVACopedia app and keep the whole library on your phone for jobs with no signal.

Open the app

Source: Daikin 3P761829-1B FIT outdoor unit DC6VS/DH6VS/DC9VSA/DH7VSA installation & service reference, Troubleshooting table p.44 (printed page). Summarized in our own words; check the original manual for your model.

Homeowner looking at this code? See what it means for you and when to call a technician.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.